Efficacy of digital pupillometry for diagnosis of Horner syndrome

نویسندگان

  • Yung Ju Yoo
  • Hee Kyung Yang
  • Jeong-Min Hwang
چکیده

OBJECTIVES To evaluate the efficacy of digital pupillometry in the diagnosis of anisocoria related to Horner syndrome in adult patients. DESIGN Retrospective, observational, case control study. METHODS Nineteen patients with unilateral Horner syndrome (Horner group) and age-matched controls of 30 healthy individuals with normal vision and neither optic nerve dysfunction nor pupillary abnormalities were included. Pupillary light reflex (PLR) of the Horner group and controls were measured by a dynamic pupillometer (PLR-200; NeurOptics Inc., Irvine, USA). Minimal and maximal (min/max) pupil diameters, latency, constriction ratio, constriction velocity, dilation velocity, and total time taken by the pupil to recover 75% of maximal pupil diameter (T75) were noted. PLR were measured at baseline in both groups and at 30-45 minutes later after 0.5% apraclonidine (Iopidine®; Alcon Laboratories, Fort Worth, TX, USA) instillation in the Horner group. MAIN OUTCOME MEASURES The PLR parameters in the affected eye and inter-eye difference before and after 0.5% apraclonidine instillation. RESULTS In the Horner group, pupil diameters and T75 showed significant difference between the affected eye and unaffected contralateral eye at baseline (all P<0.00625). Compared to controls, inter-eye difference values of pupil diameters and T75 were significantly larger in the Horner group (all P<0.001). After 0.5% apraclonidine instillation, changes in pupil diameter and constriction ratio were significantly larger in the affected eye compared to the unaffected contralateral eye (all P<0.00625). The area under the receiver operating characteristic curves for diagnosing Horner syndrome were largest for baseline inter-eye difference in min/max pupil sizes (AUC = 0.975, 0.994), T75 (AUC = 0.838), and change in min/max pupil sizes after apraclonidine instillation (AUC = 0.923, 0.929, respectively). The diagnostic criteria for Horner syndrome relying on baseline pupillary measurements was defined as one of the two major findings; 1) smaller maximal pupil diameter in the affected eye with an inter-eye difference of > 0.5 mm, or 2) T75 > 2.61 seconds in the affected eye, which showed a sensitivity of 94.7% and specificity of 93.3%. The diagnostic accuracy of apraclonidine testing showed a sensitivity of 84.6% and specificity of 92.3%. CONCLUSIONS Digital pupillometry is an objective method for quantifying PLR. Baseline inter-eye difference in maximal pupil sizes and dilation lag measured by T75 was equally effective in the diagnosis of Horner syndrome compared to the reversal of anisocoria after apraclonidine instillation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early diagnosis of Horner syndrome using topical apraclonidine.

The diagnosis of Horner syndrome (HS) using apraclonidine eye drops is an alternative to the use of topical cocaine drops. A number of reports have described the efficacy of apraclonidine testing, but there is some debate over its sensitivity in the acute setting. We describe a patient with HS secondary to carotid dissection who had a positive response to apraclonidine 3 hours after the onset o...

متن کامل

Comparing efficacies of 0.5% apraclonidine with 4% cocaine in the diagnosis of horner syndrome in pediatric patients.

PURPOSE The aim of this study was to compare the efficacy of 0.5% apraclonidine with that of 4% cocaine and to evaluate its safety in the diagnosis of Horner syndrome in pediatric patients. METHODS This was a randomized, crossover study, wherein 10 patients with a probable diagnosis of Horner syndrome were assigned to undergo pharmacological testing with 4% cocaine and 0.5% apaconidine. The d...

متن کامل

Ultrasound diagnosis of spontaneous carotid dissection with isolated Horner syndrome.

BACKGROUND AND PURPOSE Isolated Horner syndrome without associated cranial nerve palsies or ischemic symptoms is an important presentation of spontaneous internal carotid artery dissection (sICAD). Ultrasound is often used as a screening method in these patients because cervical MRI is not always available on an emergency basis. Current knowledge on ultrasound findings in patients with sICAD pr...

متن کامل

Comparison of the Efficacy of Digital Caliper and a Newly Designed Digital Bone Gauge for Measurement of Edentulous Alveolar Ridge Width

Objectives: An efficient, safe, affordable and easily accessible measuring instrument for quantitative assessment of bone prior to dental implant placement enables more accurate treatment planning. Costly imaging modalities are neither widely available, nor affordable for some patients. This study sought to assess the efficacy of a newly designed digital bone gauge for measurement of bone width...

متن کامل

[Usefulness of apraclonidine in the diagnosis of Horner syndrome].

CASE REPORTS We present four cases: two males with Horner Syndrome, who were diagnosed by means of apraclonidine 0.5% and cocaine 4% tests respectively. Two children with anisocoria, one of whom had Horner Syndrome confirmed with apraclonidine 1% and the other, in whom an apraclonidine test ruled out this syndrome but in whom pilocarpine 0.125% confirmed Adie's pupil. DISCUSSION Apraclonidine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017