Midface lift technique with use of a biodegradable device for tissue elevation and fixation.

نویسندگان

  • R Laurence Berkowitz
  • David B Apfelberg
  • Sherry Simeon
چکیده

BACKGROUND Aesthetic surgeons have become increasingly aware that elevation of the midface is a significant component of facial rejuvenation. However, adequate fixation remains a problem in midface lift procedures, regardless of the approach. OBJECTIVE The purpose of this study was to evaluate the efficacy and ease of application of the Endotine midface device (Coapt Systems, Palo Alto, CA), as well as patient and surgeon satisfaction with the results of treatment. METHODS The Endotine device consists of a polylactide polymer that incorporates 5 tines, each 4.5 mm long, to distribute tension over a wide area, maximizing fixation strength and holding power. After the cheek tissue is engaged, upward tension is applied to the anchoring leash, which is then sutured to the deep temporal fascia. Between October 2003 and October 2004, 31 patients underwent Endotine fixation for midface lift. The patient group comprised 7 men and 24 women ranging in age from 40 to 65 years (mean age, 49.25 years). Four patients had midface lifts as the sole procedure, and 27 had adjunctive facial cosmetic procedures. Results evaluated included ease of use/difficulty of insertion, postsurgical pain, adequacy and stability of fixation, side effects and complications, and patient and surgeon satisfaction. RESULTS All patients were judged to have satisfactory cheek elevation and enhanced contour without evidence of recurrent midface ptosis or loss of elevation/fixation. There were no postoperative complications of infection, hematoma, or dehiscence. In a subset of 11 patients, "pain in the treated area" averaged 2.7 (0 = no pain, 10 = extreme pain) at one month follow-up. Surgeon satisfaction with the fixation result averaged 4.9 (1 = very dissatisfied, 5 = very satisfied) at one month follow-up. Patient self-assessment of aesthetic outcome averaged 3.8 (1 = worse than baseline, 4 = dramatic improvement from baseline) at one month follow-up, and patient satisfaction assessment averaged 3.9 (1 = very dissatisfied, 4 = very satisfied) at one month follow-up. CONCLUSIONS The midface Endotine device provided rapid, secure fixation in our small patient study group without complications, and eliminated the complicated and awkward suture techniques that have been an impediment to midface surgery. Larger clinical studies are in progress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subperiosteal Endotine-assisted vertical upper midface lift.

BACKGROUND In the typical upper midface lift, tissue fixation is usually accomplished through a series of sutures that may be time consuming, technically demanding, difficult to apply, and also require frequent rearrangement and adjustment. OBJECTIVE The use of an Endotine Midface (Coapt Systems, Palo Alto, CA) fixation device through a technique termed the subperiosteal Endotine-assisted ver...

متن کامل

Thirteen years of experience with the endoscopic midface lift.

BACKGROUND Numerous techniques have been used to rejuvenate the aging midface. The Endotine midface technique involves an endoscopic temporal approach, including midface dissection and malar suspension with fixation. The Endotine device (Microaire, Charlottesville, Virginia) eliminates the intraoral incision and use of sutures, enabling multipoint fixation and fast, simple adjustability for opt...

متن کامل

Endoscopic temporal-incision only midface lift is enhanced by endotine technique.

The Endotine midface technique, through an endoscopic temporal-incision only approach, is the author's preferred method of malar fat pad suspension and fixation. The bioabsorbable Endotine device avoids an intraoral incision, eliminates sutures, offers multipoint fixation, and the leash fixation mechanism provides fast and simple adjustability for optimal control of midface elevation and volume.

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Safety and efficacy of midface-lifts with an absorbable soft tissue suspension device.

OBJECTIVE To evaluate the safety and efficacy of midface-lifting using an absorbable suspension device (Endotine ST). DESIGN Prospective cohort of 10 consecutive adult female patients seen in a private practice who underwent isolated midface-lift without accompanying eyelid surgery or volume augmentation procedures in the setting of an accredited ambulatory surgical center. All patients under...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aesthetic surgery journal

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 2005