BACKGROUND For yttrium-90 ((90)Y) radioembolization, the common practice of assuming a standard 1,000-g lung mass for predictive dosimetry is fundamentally incongruent with the modern philosophy of personalized medicine. We recently developed a technique of personalized predictive lung dosimetry using technetium-99m ((99m)Tc) macroaggregated albumin (MAA) single photon emission computed tomography with integrated CT (SPECT/CT) of the lung as part of our routine dosimetric protocol for (90)Y radioembolization. Its rationales are the technical superiority of SPECT/CT over planar scintigraphy, ease and convenience of lung auto-segmentation CT densitovolumetry, and dosimetric advantage of patient-specific lung parenchyma masses. METHODS This is a retrospective study of our pulmonary clinical outcomes and comparison of lung dosimetric accuracy and precision by (99m)Tc MAA SPECT/CT versus conventional planar methodology. (90)Y resin microspheres (SIR-Spheres) were used for radioembolization. Diagnostic CT densitovolumetry was used as a reference for lung parenchyma mass. Pulmonary outcomes were based on follow-up diagnostic CT chest or X-ray. RESULTS Thirty patients were analyzed. The mean lung parenchyma mass of our Southeast Asian cohort was 822 ± 103 g standard deviation (95% confidence interval 785 to 859 g). Patient-specific lung parenchyma mass estimation by CT densitovolumetry on (99m)Tc MAA SPECT/CT is accurate (bias -21.7 g) and moderately precise (95% limits of agreement -194.6 to +151.2 g). Lung mean radiation absorbed doses calculated by (99m)Tc MAA SPECT/CT and planar methodology are both accurate (bias <0.5 Gy), but (99m)Tc MAA SPECT/CT offers better precision over planar methodology (95% limits of agreement -1.76 to +2.40 Gy versus -3.48 to +3.31 Gy, respectively). None developed radiomicrosphere pneumonitis when treated up to a lung mean radiation absorbed dose of 18 Gy at a median follow-up of 4.4 months. CONCLUSIONS Personalized predictive lung dosimetry by (99m)Tc MAA SPECT/CT is clinically feasible, safe, and more precise than conventional planar methodology for (90)Y radioembolization radiation planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in SPECT for Optimizing the Liver Tumors Radioembolization Using Yttrium-90 Microspheres

Radioembolization (RE) with Yttrium-90 ((90)Y) microspheres is an effective treatment for unresectable liver tumors. The activity of the microspheres to be administered should be calculated based on the type of microspheres. Technetium-99m macroaggregated albumin ((99m)Tc-MAA) single photon emission computed tomography/computed tomography (SPECT/CT) is a reliable assessment before RE to ensure ...

متن کامل

Non-Target Activity Detection by Post-Radioembolization Yttrium-90 PET/CT: Image Assessment Technique and Case Examples

High resolution yttrium-90 ((90)Y) imaging of post-radioembolization microsphere biodistribution may be achieved by conventional positron emission tomography with integrated computed tomography (PET/CT) scanners that have time-of-flight capability. However, reconstructed (90)Y PET/CT images have high background noise, making non-target activity detection technically challenging. This educationa...

متن کامل

Quantitative comparison of yttrium-90 (90Y)-microspheres and technetium-99m (99mTc)-macroaggregated albumin SPECT images for planning 90Y therapy of liver cancer.

Yttrium-90 ((90)Y)-microspheres administered via the hepatic artery has been used for the treatment of unresectable primary or metastatic cancer in the liver. Prior to (90)Y therapy, however, the (90)Y administered activity and the percent shunting to lungs must be determined, most commonly by gamma camera imaging of technetium-99m ((99m)Tc)-macroaggregated albumin (MAA). The purpose of the cur...

متن کامل

Sze Microspheres : Known Proof of Effectiveness Y - Loaded 90 Based Dosimetry for Liver Cancer Treated Using −

1. Lam MGEH, Goris ML, Iagaru AH, Mittra ES, Louie JD, Sze DY. Prognostic utility of 90Y radioembolization dosimetry based on fusion 99mTc-macroaggregated albumin–99mTc-sulfur colloid SPECT. J Nucl Med. 2013;54:2055–2061. 2. Garin E, Lenoir L, Rolland Y, et al. 99mTc-MAA SPECT/CT based dosimetry accurately predicts tumour response and survival in HCC patients treated with 90Y-loaded glass micro...

متن کامل

Personalized dosimetry with intensification using 90Y-loaded glass microsphere radioembolization induces prolonged overall survival in hepatocellular carcinoma patients with portal vein thrombosis.

UNLABELLED The objective of this study was to evaluate the response rate and survival of hepatocellular carcinoma portal vein thrombosis (PVT) patients treated with (90)Y-loaded glass microspheres using a personalized dosimetry and intensification concept. METHODS The microspheres were administered to 41 hepatocellular carcinoma PVT patients (main = 12; lobar/segmental = 29). (99m)Tc-macroagg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014