Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration

نویسندگان

  • Adam G Chandler
  • Richard J Pinder
  • Thomas Netsch
  • Julia A Schnabel
  • David J Hawkes
  • Derek LG Hill
  • Reza Razavi
چکیده

A popular technique to reduce respiratory motion for cardiovascular magnetic resonance is to perform a multi-slice acquisition in which a patient holds their breath multiple times during the scan. The feasibility of rigid slice-to-volume registration to correct for misalignments of slice stacks in such images due to differing breath-hold positions is explored. Experimental results indicate that slice-to-volume registration can compensate for the typical misalignments expected. Correction of slice misalignment results in anatomically more correct images, as well as improved left ventricular volume measurements. The interstudy reproducibility has also been improved reducing the number of samples needed for cardiac MR studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Motion correction in fMRI via registration of individual slices into an anatomical volume.

An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired in the same fMRI session to accommodate inter-slice head motion. Accuracy of the registration para...

متن کامل

Inter-slice motion correction using spatiotemporal interpolation for functional magnetic resonance imaging of the moving fetus

Fetal motion continues to be one of the major artifacts in in-utero functional MRI; interestingly few methods have been developed to address fetal motion correction. In this study, we propose a robust method for motion correction in fetal fMRI by which both inter-slice and inter-volume motion artifacts are jointly corrected. To accomplish this, an original volume is temporally split into odd an...

متن کامل

Super-resolution for real-time volumetric MR temperature imaging

Recently, real time magnetic resonance (MR) thermometry has evolved into the method of choice for the guidance of non-invasive ablation modalities such as highintensity focused ultrasound (HIFU). For this role MR-thermometry should preferably have a high temporal and spatial resolution and allow observing the temperature over the entire target area with a high precision. This is in practice dif...

متن کامل

Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

PURPOSE A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultaneously acquired slice-group. These navigator data may contain spatially nonlin...

متن کامل

Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study

BACKGROUND In patients with ischemic heart disease, accurate assessment of the extent of myocardial perfusion deficit may be important in predicting prognosis of clinical cardiac outcomes. The aim of this study was to compare the ability of three dimensional (3D) and of two dimensional (2D) multi-slice myocardial perfusion imaging (MPI) using cardiovascular magnetic resonance (CMR) in determini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Cardiovascular Magnetic Resonance

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2008