Effects of Sulfate, Chloride, and Bicarbonate on Iron Stability in a PVC-U Drinking Pipe
نویسندگان
چکیده
In order to describe iron stability in plastic pipes and to ensure the drinking water security, the influence factors and rules for iron adsorption and release were studied, dependent on the Unplasticized poly (vinyl chloride) (PVC-U) drinking pipes employed in this research. In this paper, sulfate, chloride, and bicarbonate, as well as synthesized models, were chosen to investigate the iron stability on the inner wall of PVC-U drinking pipes. The existence of the three kinds of anions could significantly affect the process of iron adsorption, and a positive association was found between the level of anion concentration and the adsorption rate. However, the scaling formed on the inner surface of the pipes would be released into the water under certain conditions. The Larson Index (LI), used for a synthetic consideration of anion effects on iron stability, was selected to investigate the iron release under multi-factor conditions. Moreover, a well fitted linear model was established to gain a better understanding of iron release under multi-factor conditions. The simulation results demonstrated that the linear model was better fitted than the LI model for the prediction of iron release.
منابع مشابه
Impact of Piping Materials on Water Quality in Tegucigalpa, Honduras
The possible effects of pipe materials on drinking water quality have been analyzed in the distribution system of the water treatment plant of “La Concepción” in Tegucigalpa, Honduras. “La Concepción” is a surface water reservoir experiencing biogeochemical cycling of manganese. Black water problems have been reported in the distribution system since 1998. An evaluation of the potential influen...
متن کاملModeling and Control of Vinyl Chloride in Drinking Water Distribution Systems
In water distribution systems containing PVC pipe manufactured in the ‘‘early era’’ ~prior to 1977!, vinyl chloride can leach into drinking water resulting in vinyl chloride concentrations exceeding the 2 mg•L maximum contaminant level. Field testing of dead-end segments of water distribution systems consisting of early-era PVC pipe was conducted to examine their initial intrapipe vinyl chlorid...
متن کاملChlorine decay and DBP formation under different flow regions in PVC and ductile iron pipes: Preliminary results on the role of flow velocity and radial mass transfer
A systematic experimental study was conducted using a pilot-scale drinking water distribution system simulator to quantify the effect of hydrodynamics, total organic carbon (TOC), initial disinfectant levels, and pipe materials on chlorine decay and disinfection byproduct (DBP) formation. The first phase of the experiments focused on the variables of flow rate and pipe materials and their effec...
متن کاملHotspots for selected metal elements and microbes accumulation and the corresponding water quality deterioration potential in an unchlorinated drinking water distribution system.
Biofilm formation, loose deposit accumulation and water quality deterioration in drinking water distribution systems have been widely reported. However, the accumulation and distribution of harbored elements and microbes in the different niches (loose deposits, PVC-U biofilm, and HDPE biofilm) and their corresponding potential contribution to water quality deterioration remain unknown. This pre...
متن کاملWaterhammer tests in a long PVC pipeline with short steel end sections
An experiment featuring waterhammer in viscoelastic pipes is presented in which the effects of pipe-wall viscoelasticity on waterhammer pressures are investigated. A large-scale pipeline apparatus made of polyvinyl chloride (PVC) at Deltares, Delft, The Netherlands, has been used to carry out waterhammer experiments. Tests have been conducted in a reservoir-pipeline-valve system consisting of a...
متن کاملذخیره در منابع من