Evaluation of two Humphrey perimetry programs: full threshold and SITA standard testing strategy for learning effect.

نویسندگان

  • O Yenice
  • A Temel
چکیده

PURPOSE To compare learning effect of Swedish interactive threshold algorithm (SITA) standard strategy with full threshold testing. METHODS Thirty-nine medical students with no experience in visual field testing had full threshold (FT) and SITA standard for either right or left eyes. They were chosen in such a way that 20 (Group I) had FT for right and SITA for left eyes and 19 (Group II) had SITA standard for right and FT for left eyes. It was designed to have both strategies on same person whereby eliminating inter-individual variability. Visual field testing was repeated in the same week of the first test on the same subject with the same strategy that was chosen for that eye. RESULTS The authors found an improvement in mean deviation (MD) and pattern standard deviation (PSD) of first and second testings correspondingly for FT (MD from -3.04 to -2.55; PSD from -2.60 to -2.29) and SITA standard (MD from -2.86 to -2.20; PSD from 2.25 to 2.10) and changes were statistically significant (p<0.05). To analyze learning effect of visual field testings, we calculated percentage change in MD and PSD for full threshold and SITA standard strategy. The percentage changes in visual field parameters were significantly lower in SITA standard strategy testing for MD (p=0.02) and PSD (p=0.01). CONCLUSIONS This study shows that a learning effect is present for both strategies and SITA standard may have a reduced learning effect compared to FT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of threshold estimation and learning effect of two perimetric strategies, SITA Fast and CLIP, in damaged visual fields.

PURPOSE The threshold estimation, learning effect, and between-algorithm differences of the Fast Swedish Interactive Thresholding Algorithm (SITA Fast), of the Humphrey Field Analyzer (HFA), and the Continuous Light Increment Perimetry (CLIP) strategy of the Oculus Twinfield perimeter were evaluated in damaged visual fields. METHODS Twenty-one glaucomatous patients with damaged visual fields ...

متن کامل

Glaucoma follow-up when converting from long to short perimetric threshold tests.

OBJECTIVES To study the influence of test length in automated perimetry follow-up of glaucomatous eyes and, particularly, to determine if it is possible to usefully interpret test results obtained using a testing algorithm shorter than that used for baseline testing. METHODS Automated perimetry findings were retrospectively evaluated in 31 patients with glaucoma for whom multiple Humphrey 30-...

متن کامل

A comparison of perimetric results with the Medmont and Humphrey perimeters.

BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...

متن کامل

Sensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma

Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field ...

متن کامل

Between-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.

PURPOSE To determine the between-algorithm differences in perimetric sensitivity for the Swedish Interactive Threshold algorithm (SITA) Standard, SITA Fast, FASTPAC, and Full Threshold algorithms; to determine the between-subject, between-algorithm differences in the magnitude of the normal variation in sensitivity. METHODS The sample comprised 50 normal subjects (mean age, 52.9 +/- 18.5 year...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2005