Behavioral hearing thresholds between 0.125 and 20 kHz using depth-compensated ear simulator calibration.
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to obtain behavioral hearing thresholds for frequencies between 0.125 and 20 kHz from a large population between 10 and 65 yr old using a clinically feasible calibration method expected to compensate well for variations in the distance between the eardrum and an insert-type sound source. Previous reports of hearing thresholds in the extended high frequencies (>8 kHz) have either used calibration techniques known to be inaccurate or specialized equipment not suitable for clinical use. DESIGN Hearing thresholds were measured from 352 human subjects between 10 and 65 yr old having clinically normal-hearing thresholds (<20 dB HL) up to 4 kHz. An otoacoustic emission probe fitted with custom sound sources was used, and the stimulus levels individually tailored on the basis of an estimate of the insertion depth of the measurement probe. The calibrated stimulus levels were determined on the basis of measurements made at various depths of insertion in a standard ear simulator. Threshold values were obtained for 21 frequencies between 0.125 and 20 kHz using a modified Békésy technique. Forty-six of the subjects returned for a second measurement months later from the initial evaluation. RESULTS In agreement with previous reports, hearing thresholds at extended high frequencies were found to be sensitive to age-related changes in auditory function. In contrast with previous reports, no gender differences were found in average hearing thresholds at most evaluated frequencies. Two aging processes, one faster than the other in time scale, seem to influence hearing thresholds in different frequency ranges. The standard deviation (SD) of test-retest threshold difference for all evaluated frequencies was 5 to 10 dB, comparable to that reported in the literature for similar measurement techniques but smaller than that observed for data obtained using the standard clinical procedure. CONCLUSIONS The depth-compensated ear simulator-based calibration method and the modified Békésy technique allow reliable measurement of hearing thresholds over the entire frequency range of human hearing. Hearing thresholds at the extended high frequencies are sensitive to aging and reveal subtle differences, which are not evident in the frequency range evaluated regularly (≤8 kHz). Previously reported gender-related differences in hearing thresholds may be related to ear-canal acoustics and the calibration procedure and not because of differences in hearing sensitivity.
منابع مشابه
Comparison of nine methods to estimate ear-canal stimulus levels.
The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion d...
متن کاملComparing the Accuracy and Speed of Manual and Tracking Methods of Measuring Hearing Thresholds.
OBJECTIVES The reliability of hearing thresholds obtained using the standard clinical method (modified Hughson-Westlake) has been the focus of previous investigation given the potential for tester bias (). In recent years, more precise methods in laboratory studies have been used that control for sources of bias, often at the expense of longer test times. The aim of this pilot study was to comp...
متن کاملCharacteristics of the 2f(1)-f(2) distortion product otoacoustic emission in a normal hearing population.
Distortion-product otoacoustic emission (DPOAE) fine structure and component characteristics are reported between 0.75 and 16 kHz in 356 clinically normal hearing human subjects ages 10 to 65 yr. Stimulus tones at 55/40, 65/55, and 75/75 dB SPL were delivered using custom designed drivers and a calibration method that compensated for the depth of insertion of the otoacoustic emission (OAE) prob...
متن کاملثبت دگرسویی آستانههای پاسخ پایدار شنوایی
Background & Aim:Auditory steady�state response (ASSR) is an oscillation in the electrical potential recorded from the scalp. In this study, the possible effects of shifting the response recording channel on 40Hz ASSR thresholds and their recording times were evaluated and compared.Patients and Method:In this cross-sectional�study, 30 subjects with normal hearing (thresholds of 500 to 4000 ...
متن کاملبررسی دقت تخمین آستانه شنوایی بهنجار بوسیله پاسخهای برانگیخته قشر شنوایی
Background: Cortical Evoked Response Audiometry (CERA) refers to prediction of behavioral pure-tone thresholds (500-4000 Hz) obtained by recording the N1-P2 complex of auditory long latency responses. CERA is the preferred method for frequency–specific estimation of audiogram in conscious adults and older children. CERA has an increased accuracy of determination of the hearing thresholds of ale...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ear and hearing
دوره 33 3 شماره
صفحات -
تاریخ انتشار 2012