Direct Statistical Parametric Image Estimation for Linear Pharmacokinetic Models from Quantitative Positron Emission Tomography Measurements

نویسندگان

  • Charalampos Tsoumpas
  • Kris Thielemans
  • Federico Turkheimer
چکیده

In dynamic PET studies, the changing activity of the radiotracer is measured through multiple consecutive time frames. Subsequently, the radioactivity distribution for each frame is obtained by a method known as reconstruction. Then, the distribution of the physiological parameter of interest is estimated by applying an appropriate pharmacokinetic model. Thus, the kinetic parameters are obtained indirectly through a two-step process. If the two steps are combined by incorporating the pharmacokinetics of the measured counts into the reconstruction, the directly reconstructed parametric images are expected to be of higher quality and accuracy. Both indirect and direct parametric estimation methods have been implemented, evaluated and compared for the case where the kinetic model is linear in the pharmacokinetic parameters and displays irreversible behaviour (i.e. Patlak plot). The main aim of this study is the investigation of the statistical properties of different approaches. For the indirect estimation, the tracer distribution during each frame is estimated with filtered back projection (FBP) and ordered subsets expectation maximization (OSEM). Then, the pharmacokinetic parameters are estimated by the Patlak plot. These indirect procedures are compared with a direct parametric reconstruction method which integrates the Patlak plot into the OSEM optimization (POSEM). The resolution of noiseless reconstructions appeared appreciable lower for the analytically estimated parametric images comparing to those estimated iteratively. In order to investigate other sources of disparities between analytical and iterative methods, the latter were post-filtered to match resolution. The post-filtered images demonstrated similar bias for all methods in the most regions but less standard deviation for OSEM and even less for POSEM. Nevertheless, POSEM converged slowly in some regions and this feature is a general characteristic of this algorithm. Finally, optimization approaches are proposed which may improve the convergence rate and hence the quantification of the pharmacokinetic parameters. E-mail: [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct Estimation of Kinetic Parametric Images for Dynamic PET

Dynamic positron emission tomography (PET) can monitor spatiotemporal distribution of radiotracer in vivo. The spatiotemporal information can be used to estimate parametric images of radiotracer kinetics that are of physiological and biochemical interests. Direct estimation of parametric images from raw projection data allows accurate noise modeling and has been shown to offer better image qual...

متن کامل

Comparison of Count Normalization Methods for Statistical Parametric Mapping Analysis Using a Digital Brain Phantom Obtained from Fluorodeoxyglucose-positron Emission Tomography

Objective(s): Alternative normalization methods were proposed to solve the biased information of SPM in the study of neurodegenerative disease. The objective of this study was to determine the most suitable count normalization method for SPM analysis of a neurodegenerative disease based on the results of different count normalization methods applied on a prepared digital phantom similar to one ...

متن کامل

Generalized linear least squares algorithms for modeling glucose metabolism in the human brain with corrections for vascular effects

The generalized linear least squares (GLLS) algorithm has been found useful in image-wide parameter estimation for the generation of parametric images with positron emission tomography (PET) as it is computationally efficient and statistically reliable. However, the original algorithm was designed for parameter estimation with non-uniformly sampled instantaneous measurements. When dynamic PET d...

متن کامل

A survey of approaches for direct parametric image reconstruction in emission tomography.

The quantitative data obtained by emission tomography are decoded using a number of techniques and methods in sequence to provide physiological information. Conventionally, the data are reconstructed to produce a series of static images. Then, pharmacokinetic modeling techniques are applied, and kinetic parameters that have physiological or functional significance are derived. Although it is po...

متن کامل

Statistical approaches in quantitative positron emission tomography

Positron emission tomography is a medical imaging modality for producing 3D images of the spatial distribution of biochemical tracers within the human body. The images are reconstructed from data formed through detection of radiation resulting from the emission of positrons from radioisotopes tagged onto the tracer of interest. These measurements are approximate line integrals from which the im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008