Enzyme immunoassay of estriol in pregnancy urine.
نویسندگان
چکیده
We describe an enzyme immunoassay for determination of total estriol in urine. Estriol covalently bound to horseradish peroxidase is used as tracer, and free and bound hormone are separated by precipitation with polyethylene glycol. The method can be used with either acid hydrolysis at 100 degrees C for 30 min or enzyme hydrolysis at 50 degrees C for 40 min; results by the former procedure are about 15% lower than results by the latter. Results were practically identical when we compared the enzyme immunoassay with a radioimmunoassay, using the same antiserum and method of hydrolysis. The day-to-day CV for three different concentrations was 10.7-12.0%, the within-series CV 6.6-8.6%. The additional time required for the enzyme reaction is compensated for by the rapid measurement of light absorbance. Thus this method is faster than radioimmunoassay when more than 25 samples are to be assayed.
منابع مشابه
Enzyme immunoassay of estrogen-like substances in plasma, with polyethylene glycol as precipitant.
We devised an enzyme immunoassay for plasma estrogen-like substances in pregnancy, using estriol covalently linked to horseradish peroxidase. Free and bound steroid were separated by use of polyethylene glycol reagent. The assay satisfies the normal criteria of specificity and precision. Results obtained by radioimmunoassay and enzyme immunoassay agreed well. Our assay is particularly applicabl...
متن کاملAnalysis of triple test results in 27 cases of twin pregnancies.
The study comprises 889 pregnant women between 14 and 21 weeks of gestation. The control group consisted of 862 pregnant women with unburdened obstetric anamnesis with an uneventful singleton pregnancy. The examined group consisted of 27 pregnant women with uncomplicated twin pregnancy. In the sera of pregnant women AFP (Microparticle Enzyme Immunoassay AxSYM Abbott), total beta-hCG (Microparti...
متن کاملImmunoassay of estradiol: unanticipated suppression by unconjugated estriol.
BACKGROUND Accurate measurement of estradiol is important in clinical settings. The quality of laboratory estimations of estradiol may be assessed through external quality-assurance surveys. METHODS Estradiol was measured by microparticle enzyme immunoassay (MEIA) and other immunoassays. Proficiency testing of medical laboratories was conducted using samples prepared from normal male human se...
متن کاملA semi-automated fluorometric method for total estrogens in pregnancy urine.
We report a continuous-flow fluorometric method for total urinary estrogens that involves the Kober reaction, with extraction of the reaction product into dichloroethane containing trichloroacetic acid as described by Hahnel and Jones [Clin. Chim. Acta 16, 185 (1967)]. The dichloroethane extraction gives greater stability to the Kober color and sharper separation of aqueous and organic phases. ...
متن کاملContribution of estriol to total urinary estrogens during pregnancy.
Estriol accounts for an average of 74% of the principal Kober-positive steroids in the urine of 13 women during uncomplicated pregnancies. This proportion is independent of the stage of pregnancy, from 20 weeks until term. The average ratio of estriol to ring-D a#{149}ketols (mainly 16ahydroxyestrone and 16-ketoestradiol-17) is about 5:1 over the same period. In 17 pregnant women with diabetes,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 26 13 شماره
صفحات -
تاریخ انتشار 1980