Target analyte quantification by isotope dilution LC-MS/MS directly referring to internal standard concentrations--validation for serum cortisol measurement.

نویسندگان

  • Barbara Maier
  • Michael Vogeser
چکیده

BACKGROUND Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [direct isotope dilution analysis (DIDA)] may be not inferior to conventional external calibration with respect to accuracy and reproducibility. METHODS Quality control samples and human serum pools were analysed in a comparative validation protocol for cortisol as an exemplary analyte by LC-MS/MS. Accuracy and reproducibility were compared between quantification either involving a six-point external calibration function, or a result calculation merely based on peak area ratios of unlabelled and labelled analyte. RESULTS Both quantification approaches resulted in similar accuracy and reproducibility. CONCLUSIONS For specified analytes, reliable analyte quantification directly derived from the ratio of peak areas of labelled and unlabelled analyte without the need for a time consuming multi-point calibration series is possible. This DIDA approach is of considerable practical importance for the application of LC-MS/MS in the clinical laboratory where short turnaround times often have high priority.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.

Cortisol is an important diagnostic marker for the production of steroid hormones, and accurate measurements of serum cortisol are necessary for proper diagnosis of adrenal function. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically e...

متن کامل

Candidate Reference Measurement Procedure for the Quantification of Total Serum Cortisol with LC-MS/MS.

BACKGROUND Accurate measurement of serum cortisol is required to diagnose and treat adrenal disorders. Although certified reference materials (CRMs) are available to standardize cortisol measurements, External Quality Assessment (EQA) schemes still demonstrate a wide dispersion of results. We present a serum cortisol candidate reference measurement procedure that, through analysis of a Joint Co...

متن کامل

LC-MS/MS Validation Analysis of Trastuzumab Using dSIL Approach for Evaluating Pharmacokinetics.

Quantitative targeted proteomics based approaches deploy state-of-the-art Liquid chromatography tandem mass spectrometry LC-MS technologies and are evolving as a complementary technique to standard ligand-binding based assays. Advancements in MS technology, which have augmented the specificity, selectivity and sensitivity limits of detection and freedom from antibody generation, have made it am...

متن کامل

Quantification of vancomycin in human serum by LC-MS/MS.

BACKGROUND The aim of our work was to develop and validate a reliable LC-MS/MS-based measurement procedure for the quantification of vancomycin in serum, to be applied in the context of efforts to standardize and harmonize therapeutic drug monitoring of this compound using routine assays. METHODS Sample preparation was based on protein precipitation followed by ultrafiltration. In order to mi...

متن کامل

Validation of a Cannabinoid Quantitation Method Using an Agilent 6430 LC/MS/MS Authors

A method was developed and validated for the quantitation of cannabinoids with LC/MS/MS using an Agilent 6430 Triple Quadrupole LC/MS system. Validation showed that the LC/MS/MS method provides reliable results for the quantitation of THC, OH-THC, and carboxy-THC that meet predetermined acceptance criteria [1]. The concentration range of target compounds used in this validation was chosen to fi...

متن کامل