Computer-assisted ex vivo, normothermic small bowel perfusion.

نویسندگان

  • M J Stangl
  • J Krapp
  • D Theodorou
  • M Eder
  • C Hammer
  • W Land
  • F W Schildberg
چکیده

BACKGROUND In the present study, a technique for computer-assisted, normothermic, oxygenated, ex vivo, recirculating small bowel perfusion was established as a tool to investigate organ pretreatment protocols and ischemia/reperfusion phenomena. A prerequisite for the desired setup was an organ chamber for ex vivo perfusion and the use of syngeneic whole blood as perfusate. METHODS The entire small bowel was harvested from Lewis rats and perfused in an organ chamber ex vivo for at least 2 h. The temperature was kept at 37 degrees C in a water bath. Three experimental groups were explored, characterized by different perfusion solutions. The basic perfusate consisted of syngeneic whole blood diluted with either NaCl, Krebs' solution or Krebs' solution and norepinephrine to a hematocrit of 30%. In addition, in each group l-glutamine was administered intraluminally. The desired perfusion pressure was 100 mm Hg which was kept constant with a computer-assisted data acquisition software, which measured on-line pressure, oxygenation, flow, temperature and pH and adjusted the pressure by changing the flow via a peristaltic pump. The viability of the preparation was tested by measuring oxygen consumption and maltose absorption, which requires intact enzymes of the mucosal brush border to break down maltose into glucose. RESULTS Organ perfusion in group 1 (dilution with NaCl) revealed problems such as hypersecretion into the bowel lumen, low vascular resistance and no maltose uptake. In contrast a viable organ could be demonstrated using Krebs' solution as dilution solution. The addition of norepinephrine led to an improved perfusion over the entire perfusion period. Maltose absorption was comparable to tests conducted with native small bowel. Oxygen consumption was stable during the 2-hour perfusion period. CONCLUSIONS The ex vivo perfusion system established enables small bowel perfusion for at least 2 h. The viability of the graft could be demonstrated. The perfusion time achieved is sufficient to study leukocyte/lymphocyte interaction with the endothelium of the graft vessels. In addition, a viable small bowel, after 2 h of ex vivo perfusion, facilitates testing of pretreatment protocols for the reduction of the immunogenicity of small bowel allografts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ischemia/reperfusion during normothermic perfusion.

INTRODUCTION Cold storage of organs for preservation and transplantation is reaching its limits especially with extended criteria for heart beating donors and donation after cardiac death. We will discuss recent findings and perspectives in normothermic kidney preservation. METHODS A literature review was performed from original articles and syntheses selected by the search engine PubMed. Key...

متن کامل

Normothermic Ex Vivo Kidney Perfusion for the Preservation of Kidney Grafts prior to Transplantation

Kidney transplantation has become a well-established treatment option for patients with end-stage renal failure. The persisting organ shortage remains a serious problem. Therefore, the acceptance criteria for organ donors have been extended leading to the usage of marginal kidney grafts. These marginal organs tolerate cold storage poorly resulting in increased preservation injury and higher rat...

متن کامل

Hyperbaric Sub-Normothermic Ex-Vivo Perfusion Delays the Onset of Acute Rejection in a Porcine VCA Model.

INTRODUCTION: Vascularized composite allotransplantation (VCA) offers superior functional recovery following devastating maxillofacial and upper limb injuries compared to traditional reconstructive techniques. Here, we evaluate the efficacy of a novel sub-normothermic (SN) ex-vivo perfusion strategy using hyper-oxygenated University of Wisconsin (UW) solution to mitigate reperfusion injury (RI)...

متن کامل

Criteria for Viability Assessment of Discarded Human Donor Livers during Ex Vivo Normothermic Machine Perfusion

Although normothermic machine perfusion of donor livers may allow assessment of graft viability prior to transplantation, there are currently no data on what would be a good parameter of graft viability. To determine whether bile production is a suitable biomarker that can be used to discriminate viable from non-viable livers we have studied functional performance as well as biochemical and his...

متن کامل

Normothermic ex vivo allograft blood perfusion in clinical heart transplantation.

BACKGROUND Cold ischemia associated with cold static storage is an independent risk factor for primary allograft failure and survival of patients after orthotopic heart transplantation. The effects of normothermic ex vivo allograft blood perfusion on outcomes after orthotopic heart transplantation compared to cold static storage have been studied. METHODS In this prospective, nonrandomized, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European surgical research. Europaische chirurgische Forschung. Recherches chirurgicales europeennes

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2000