Characterization of gangliosides by direct inlet chemical ionization mass spectrometry.

نویسندگان

  • T Argia
  • R K Yu
  • T Miyatake
چکیده

Permethylated derivatives of N-acetylneuraminic acid-containing GM3, N-glycolylneuraminic acid-containing GM3, GD1a, and GD1b, were analyzed by direct inlet ammonia chemical ionization (CI) mass spectrometry. These compounds were found to yield simple fragmentations, prominent fragment ions in the high mass region, and characteristic fragment ions corresponding to the cleavage of glycosidic linkages. This method also provides detailed information on the carbohydrate sequence and lipophilic composition in gangliosides.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of GM, ganglioside by direct inlet chemical ionization mass spectrometry

Intact permethylated and permethylated-reduced (LiAlH4) derivatives of GM1 ganglioside were analyzed by direct inlet ammonia chemical ionization (CI) mass spectrometry. In addition, the trimethylsilylated derivative of the permethylated-reduced sample of this ganglioside was similarly analyzed. CI mass spectrometry proves to be a highly satisfactory method for structural studies of GMI ganglios...

متن کامل

Localization and imaging of gangliosides in mouse brain tissue sections by laserspray ionization inlet.

A new ionization method for the analysis of fragile gangliosides without undesired fragmentation or salt adduction is presented. In laserspray ionization inlet (LSII), the matrix/analyte sample is ablated at atmospheric pressure, and ionization takes place in the ion transfer capillary of the mass spectrometer inlet by a process that is independent of a laser wavelength or voltage. The softness...

متن کامل

Transmission Geometry Laserspray Ionization Vacuum Using an Atmospheric Pressure Inlet

This represents the first report of laserspray ionization vacuum (LSIV) with operation directly from atmospheric pressure for use in mass spectrometry. Two different types of electrospray ionization source inlets were converted to LSIV sources by equipping the entrance of the atmospheric pressure inlet aperture with a customized cone that is sealed with a removable glass plate holding the matri...

متن کامل

Characterization of glycosphingolipids by direct inlet chemical ionization mass spectrometry.

Permethylated derivatives of cerebrosides and ceramide di-, tri-, tetra-, and penta-hexosides were analyzed by the direct inlet ammonia chemical ionization (CI) mass spectrometry. In the CI mass spectra, the fragment ions produced by the loss of methanol from the protonated molecular ion were observed in all of the glycosphingolipids. Other fragment ions due to the cleavage of glycosidic moiety...

متن کامل

Structural characterization of gangliosides isolated from mullet milt using electrospray ionization-tandem mass spectrometry.

Electrospray ionization (ESI) coupled with tandem mass spectrometry has been used in conjunction with microwave-mediated saponification, periodate oxidation, and clostridial sialidase hydrolysis to enable detailed structural characterization of gangliosides and their derivatives present in mullet milt. The gangliosides extracted from mullet milt were determined to be GM3, GM3 lactone, GM3 methy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of lipid research

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 1982