BASIC SCIENCE INVESTIGATIONS Absolute Quantification of Myocardial Blood Flow with H2O and 3-Dimensional PET: An Experimental Validation
نویسندگان
چکیده
The purpose of this study was to assess a 3-dimensional (3D)– only PET scanner (ECAT EXACT3D) for its use in the absolute quantification of myocardial blood flow (MBF) using H2O. Methods: Nine large white pigs were scanned with H2O and C15O before and after partially occluding the circumflex (n 4) or the left anterior descending (n 5) coronary artery at rest and during hyperemia induced by intravenous dipyridamole. Radioactive microspheres labeled with either 57Co or 46Sc were injected during each of the H2O scans, which allowed comparison between microsphere and PET measurements of regional MBF. PET analyses of 3D acquisition data were performed using filtered backprojection reconstruction and region-of-interest definition by factor and cluster analysis techniques and single-compartment model quantification. Results: The Hanning filter applied in image reconstruction resulted in a left atrial blood volume recovery factor of 0.84 0.06. Differences between repeated measurements of recovery were small (mean, 0.8%; range, 6.6% to 3.6%). In 256 paired measurements of MBF ranging from 0.05 to 4.4 mL . g 1 . min 1, microsphere and PET measurements were fairly well correlated. The mean difference between the 2 methods was 0.11 mL . g 1 . min 1 and the limits of agreement ( 2 SD) were 0.82 and 0.60 mL . g 1 . min 1 (Bland–Altman plot). Conclusion: Dynamic measurements with H2O using a 3D-only PET tomograph provide reliable and accurate measurements of absolute regional MBF over a wide flow range. The 3D acquisition technique can reduce the radiation dose to the subject while maintaining adequate counting statistics.
منابع مشابه
82Rb PET imaging of myocardial blood flow—have we achieved the 4 “R”s to support routine use?
Routine quantification of myocardial blood flow (MBF) in absolute units of mL/min/g has long been one of the technical milestones expected to enable the widespread clinical application of cardiac positron emission tomography (PET). The recent study by Germino et al. [1] contributes significantly to the increasing body of literature supporting the potential for rubidium-82 (Rb) PET to become the...
متن کاملMultisoftware reproducibility study of stress and rest myocardial blood flow assessed with 3D dynamic PET/CT and a 1-tissue-compartment model of 82Rb kinetics.
UNLABELLED Routine quantification of myocardial blood flow (MBF) requires robust and reproducible processing of dynamic image series. The goal of this study was to evaluate the reproducibility of 3 highly automated software programs commonly used for absolute MBF and flow reserve (stress/rest MBF) assessment with (82)Rb PET imaging. METHODS Dynamic rest and stress (82)Rb PET scans were select...
متن کاملQuantification of subendocardial and subepicardial blood flow using 15O-labeled water and PET: experimental validation.
UNLABELLED The purpose of this study was to assess the feasibility and accuracy of quantifying subendocardial and subepicardial myocardial blood flow (MBF) and the relative coronary flow reserves (CFR) using (15)O-labeled water (H(2)(15)O) and 3-dimensional-only PET. METHODS Eight pigs were scanned with H(2)(15)O and (15)O-labeled carbon monoxide (C(15)O) after partially occluding the circumf...
متن کاملPrecision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: A technical perspective.
A number of exciting advances in PET/CT technology and improvements in methodology have recently converged to enhance the feasibility of routine clinical quantification of myocardial blood flow and flow reserve. Recent promising clinical results are pointing toward an important role for myocardial blood flow in the care of patients. Absolute blood flow quantification can be a powerful clinical ...
متن کاملMyocardial blood flow measurement by PET: technical aspects and clinical applications.
The availability of plastic microspheres labeled with different -emitting isotopes has allowed the quantification of blood flow in different organs, including the heart (1). In the past 3 decades this has made it possible to study the changes in myocardial blood flow (MBF) under different physiologic and pathophysiologic conditions in experimental animals. In a similar fashion, the development ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -