Mathematical model demonstrates influence of luminal diameters on venous pressure surveillance.
نویسندگان
چکیده
BACKGROUND The reliability of dialysis venous pressure (VP) in detecting stenosis is controversial. A mathematical model may help to resolve the controversy by providing insight into the factors that influence static VP. DESIGN, SETTING, PARTICIPANTS, AND MEASUREMENTS This study used inflow artery and outflow vein luminal diameters from duplex ultrasound studies of 94 patients. These diameters were applied to a mathematical model, and how they affect the relation among VP, mean arterial pressure (MAP), blood flow, and stenosis was determined. Whether VP/MAP is a valid adjustment for the influence of MAP on VP, and whether the standard VP/MAP referral threshold of 0.50 is valid, were also determined. RESULTS It was found that there is an approximate one-to-one relation between MAP and VP, so VP/MAP is a valid adjustment. Also, the 0.50 threshold successfully identifies most grafts with stenosis of 65% or more. However, the ratio of artery/vein diameters varied widely between patients, and the ratio independently influences VP/MAP. When the inflow artery is relatively narrow, the VP/MAP increase is delayed followed by a more rapid increase as critical stenosis is reached. CONCLUSIONS VP/MAP is a valid adjustment for the influence of MAP on VP, and the standard VP/MAP threshold of 0.50 warns of the transition to critical stenosis. However, relatively narrow arteries cause a delay followed by a rapid increase in VP/MAP that may not be detected before thrombosis unless measurements are very frequent. Clinical trials that emphasize trend analysis with frequent measurements are needed to evaluate the efficacy of VP surveillance.
منابع مشابه
Influence of luminal diameters on flow surveillance of hemodialysis grafts: insights from a mathematical model.
Randomized controlled trials have not shown that surveillance of graft blood flow (Q) prolongs graft life. Because luminal diameters affect flow resistance, this study examined whether the influence of diameters on Q can explain the limitations of surveillance. Inflow artery and outflow vein diameters were determined from duplex ultrasound studies of 94 patients. These diameters were applied to...
متن کاملشبیهسازی هیدرولیکی لولههای فرعی (لترالهای) آبیاری بارانی
A computer model (SprinklerMod) was developed to simulate hydraulics of sprinkler irrigation systems. The objective of this paper is to describe mathematical background of this model for simulating pressures and discharges of sprinklers along the laterals. The model is capable of designing two types of laterals: laterals with fixed sprinklers and laterals with portable sprinklers. The model sho...
متن کاملشبیهسازی هیدرولیکی لولههای فرعی (لترالهای) آبیاری بارانی
A computer model (SprinklerMod) was developed to simulate hydraulics of sprinkler irrigation systems. The objective of this paper is to describe mathematical background of this model for simulating pressures and discharges of sprinklers along the laterals. The model is capable of designing two types of laterals: laterals with fixed sprinklers and laterals with portable sprinklers. The model sho...
متن کاملThe efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation
Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...
متن کاملMathematical Modeling of the Differential Sticking Coefficient of Clay Drilling Fluids
The main objective of this work is to propose a mathematical model for the differential sticking coefficient of clayey drilling fluids with a lubricant as an additive and evaluate the influence of differential pressure and lubricant content on filter cake thickness and permeability. Tests were carried out on fluids composed of water and 4.86% of active bentonite clay prepared in Hamilton Beach ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical journal of the American Society of Nephrology : CJASN
دوره 2 4 شماره
صفحات -
تاریخ انتشار 2007