Scour, Velocities and Pressures Evaluations Produced by Spillway and Outlets of Dam
نویسندگان
چکیده
Paute-Cardenillo (owned by Celec Ep-Hidropaute) is a dam with maximum height 135 m located in the Paute River in Ecuador. Its hydroelectric production will be integrated at the National Electric System of Ecuador with an installed capacity of 600 MW which will produce 3300 GWh per year. To evaluate the stability and safety of the structure, it is necessary to ascertain the shape and dimensions of the scour generated downstream from the dam. We studied the scour, due to the operation of the free surface spillway (700 m3/s) and half-height outlets (1760 m3/s), with three complementary procedures: empirical formulae obtained in models and prototypes, semi-empirical methodology based on pressure fluctuations-erodibility index and computational fluid dynamics simulations. The free surface weir could generate a scour around 21 m, while the intermediate outlet could reach the intact rock, located 34 m below the initial river bed. A pre-excavated basin is proposed and the velocities and pressures are analyzed. The results demonstrated the suitability of combining different methodologies to achieve an adequate resolution of this complex phenomenon.
منابع مشابه
Reduce the maximum scour depth downstream of Flip Bucket Spillway through the spillway geometry optimization (study released spillway dam Kurdistan)
The Performance of shooting pool, in addition to the quality of the area in which the flow collides with it, depends to the height of the jet drop, the angle of the water flow, the depth of the jet and the concentration of the jet. By increasing the height of the jet drop, the fall velocity increases and subsequently the jetchr('39')s energy will be more intrusive. Different collision area from...
متن کاملStudying the Effect of Submergence Depth on Scour Pattern of Hydraulic Jet Downstream
This research aims to study jet downstream scour model under the influence of changes of water level. It also studies and analyzes different parameters and components of diffusion of submerged jet flow in an acceptor fluid and scour hole dimensions. To achieve the objectives, a physical model was made in proportion to the research title. With the Froude number increasing in a nozzle discharge, ...
متن کاملOptimization and design of Adaptive Neuro-Fuzzy Inference System using Particle Swarm Optimization and Fuzzy C-Means Clustering to predict the scour after bucket spillway
Additionally, if the materials at downstream of bucket spillway are erodible, the ogee spillway is likely to overturn by the time. Therefore, the prediction of the scour after bucket spillway is pretty important. In this study, the scour depths at downstream of bucket spillway are modeled using a new meta-heuristic model. This model is developed by combination of the Adaptive Neuro-Fuzzy Infere...
متن کاملApplication of Energy Approach to Estimating Scour Depth
Many permanent spillway tunnels of high earth-rock dams are rebuilt from their diversion tunnels. Scour problem is focused because of their high water head and velocity. Energy Approach is a new method to Estimating Scour and is used here to estimate the depth of scour downstream of 1 spillway tunnel of Zipingpu Project. The method is illustrated working fine by comparing its results with data ...
متن کاملDetermination of the Height and Overtopping failure of Reservoir Dams by Using Reliability Analysis (Case Study: Namrood Dam)
Generally, the design of dams and other hydraulic structures is carried out based on deterministic approaches. However, there are many uncertainties in the estimation of different effective parameters in hydraulic structures design. The inherent uncertainties in these parameters necessitate reliability analysis to ensure the structure stability. In this study, after investigating various uncert...
متن کامل