A Self-calibration Method for the Edge Thomson Scattering Diagnostic in ITER
نویسندگان
چکیده
Calibration of spectral transmissivity of the collection and transmission optics is one of the most crucial issues for the Thomson scattering diagnostic system. Radioactivation of the vacuum vessel in ITER makes it difficult to calibrate spectral transmissivity in areas near the vacuum vessel. By using an additional calibration laser whose wavelength differs from those of the diagnostic laser and equipping two lasers with Thomson scattering lights, we can obtain the electron temperature and the relative transmissivity of each spectral channel of the polychromator from the Thomson scattering signal itself. A ruby laser is a promising candidate as a calibration laser because the wavelength does not diverge greatly from that of a diagnostic laser and from the lower limit of an observable wavelength. Even if the signal-noise ratio degrades, the available electron temperature data during calibration operations remain largely unaffected. A degrading signal-noise ratio increases statistical error in electron temperature data and relative spectral transmissivity. Even when the spectral transmissivity is unknown, electron temperature data may be obtained within a 10% margin of error, which fulfills the requirements for edge electron temperature measurement in ITER.
منابع مشابه
Thermoelectric properties of Zn5Sb4In2-δ (δ=0.15)
Related Articles A Thomson scattering diagnostic on the Pegasus Toroidal experiment Rev. Sci. Instrum. 83, 10E335 (2012) Fully automated measurement setup for non-destructive characterization of thermoelectric materials near room temperature Rev. Sci. Instrum. 83, 074904 (2012) Polychromator for the edge Thomson scattering system in ITER Rev. Sci. Instrum. 83, 10E328 (2012) Power factor enhance...
متن کاملDesign of Filters for COMPASS Thomson Scattering Diagnostics
Reinstalled tokamak COMPASS, originally from Culham Science Centre, is now operating at the Institute of Plasma Physics, Prague and many new optical diagnostics are being developed [Sestak et al, 2009]. For measurement of electron temperature and density profiles, high resolution incoherent Thomson scattering spectroscopy based on Nd:YAG laser and avalanche photodiodes is under development now....
متن کاملA polarization-based Thomson scattering technique for burning plasmas
The traditional Thomson scattering diagnostic is based on measurement of the wavelength spectrum of scattered light, where electron temperature measurements are inferred from thermal broadening of the spectrum. At sufficiently high temperatures, especially those predicted for ITER and other burning plasmas, relativistic effects cause a change in the degree of polarization (P) of the scattered l...
متن کاملPFC / JA - 93 - 25 ITER Millimeter - Wave CTS Diagnostic Option
Localized alpha-particle velocity distribution and density, ion temperature, DT fuel ratio, and internal magnetic field pitch angle can all be potentially diagnosed by a collective Thomson scattering system. Relativistic electron cyclotron calculations and TORAY ray tracing for 6 tesla ITER parameters indicate that 90 GHz is an optimum frequency for this diagnostic. With 400 kW at the plasma an...
متن کاملElectron kinetic effects on interferometry, polarimetry and Thomson scattering measurements in burning plasmas (invited).
At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP), and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. The precision of the previous lowest order linear in τ = Te/mec(2) model may be insufficient; we present a more precise model with τ(2)-or...