New generation neonatal high frequency ventilators: effect of oscillatory frequency and working principles on performance.

نویسندگان

  • Serge Grazioli
  • Oliver Karam
  • Peter C Rimensberger
چکیده

BACKGROUND Several new generation neonatal ventilators that incorporate conventional as well as high frequency ventilation (HFOV) have appeared on the market. Most of them offer the possibility to use HFOV in a volume-targeted mode, despite absence of any preclinical data. With a bench test, we evaluated the performances of 4 new neonatal HFOV devices and compared them to the SensorMedics HFOV device. METHODS Expiratory tidal volumes (V(T)) were measured for various ventilator settings and lung characteristics (ie, modifications of compliance and resistance of the system), to mimic several clinical conditions of pre-term and term infants. RESULTS Increasing the frequency proportionally decreased the V(T) for all the ventilators, although the magnitude of the decrease was highly variable between ventilators. At 15 Hz and a pressure amplitude of 60 cm H2O, the delivered V(T) ranged from 3.5 to 5.9 mL between devices while simulating pre-term infant conditions and from 2.6 to 6.3 mL while simulating term infant conditions. Activating the volume-targeted mode in the 3 machines that offer this mode allowed the V(T) to remain constant over the range of frequencies and with changes of lung mechanical properties, for pre-term infant settings only while targeting a V(T) of 1 mL. CONCLUSIONS These new generation neonatal ventilators were able to deliver adequate V(T) under pre-term infant, but not term infant respiratory system conditions. The clinical relevance of these findings will need to be determined by further studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Instructing the Principles of Endotracheal Tube Suctioning on Knowledge and Performance of Nursing Staff Working in Neonatal Intensive Care Units in Shiraz University of Medical Sciences

Introduction: Nurses must be aware of the risks regarding endotracheal tube suctioning and should have continuing education in this field. This study was performed to assess the impact of instruction on the knowledge and performance of NICU nursing staff in Shiraz University of Medical Sciences in 2006. Methods: Fifty nurses of neonatal intensive care units participated in this quasi experimen...

متن کامل

Tidal volume, recruitment and compliance in HFOV: same principles, different frequency.

T he widespread clinical introduction of high-frequency oscillatory ventilation (HFOV) for the treatment of respiratory distress syndrome in neonates in the late 1980s and early 1990s heralded a new era of understanding of the optimal approach to lung volume (VL) recruitment, which embraced the concept of open lung ventilation [1]. The promotion of HFOV as a means of independently controlling o...

متن کامل

Effects of Teaching Ergonomic Principles on Working Status in Dental Students

Background: Dentistry is considered a high-risk profession for developing musculoskeletal disorders, which can be prevented by resorting to ergonomics training. The present study was conducted to investigate the effect of ergonomics training on working status in dental students. Materials and Methods: The present quasi-interventional study was conducted in 2017 on 57 students of a clinic affili...

متن کامل

Islanding Detection and Frequency Circuit Measurement by Power Distribution Relation Depending on the Angle

This paper presents a new islanding detection method based on the difference of the power transfer angle between the distributed generation and local load. After islanding, current id and iq will be changed by adding the variation to d_q transformation block of current. This makes voltage and frequency disturbance and therefore islanding is recognized. Active islanding detection method usually ...

متن کامل

High Speed Delay-Locked Loop for Multiple Clock Phase Generation

In this paper, a high speed delay-locked loop (DLL) architecture ispresented which can be employed in high frequency applications. In order to design the new architecture, a new mixed structure is presented for phase detector (PD) and charge pump (CP) which canbe triggered by double edges of the input signals. In addition, the blind zone is removed due to the elimination of reset signal. Theref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 3  شماره 

صفحات  -

تاریخ انتشار 2015