Comparison of retinal layer intensity profiles from different OCT devices.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE The purpose of this study is to use automated multiple retinal layer segmentation to compare retinal layer intensity profiles between different spectral-domain optical coherence tomography (SD-OCT) devices with and without normalization. PATIENTS AND METHODS A graph-based multistage segmentation approach was used to identify 11 boundaries in horizontal SD-OCT B-scans passing through the foveal center. Four acquisition protocols from two different SD-OCT devices were applied on 34 eyes from 17 healthy participants. The mean intensity of the 11 layers was compared within each device and between the two devices. In addition, the intensity of the various layers was normalized against the vitreous and retinal pigment epithelium band, and the normalized intensity profiles were also compared. RESULTS Within each OCT device, the mean intensity of the 11 retinal layers did not show significant difference (P values of paired t test ranging between 0.15 and 0.30). For the two different devices, before normalization, the mean intensity of the 11 retinal layers differed significantly (P = .02 to .03). After normalization, the mean intensity no longer differed significantly (P = .26 to .51). Linear regression demonstrated an average R(2) of 0.94 (P < .001) before normalization and 0.98 (P < .001) after normalization between the two devices. CONCLUSION The morphology of the intensity profiles was found to be similar within each SD-OCT device. Comparing intensity profiles from the two different devices, significant differences in unnormalized layer intensity were observed. Following normalization, the differences between OCT devices were no longer significant.
منابع مشابه
Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study
Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...
متن کاملAutomated Retinal Layer Segmentation Using Spectral Domain Optical Coherence Tomography: Evaluation of Inter-Session Repeatability and Agreement between Devices
Retinal and intra-retinal layer thicknesses are routinely generated from optical coherence tomography (OCT) images, but on-board software capabilities and image scaling assumptions are not consistent across devices. This study evaluates the device-independent Iowa Reference Algorithms (Iowa Institute for Biomedical Imaging) for automated intra-retinal layer segmentation and image scaling for th...
متن کاملOptical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients
PURPOSE To determine the correlations and strength of association between different imaging systems in analyzing the retinal nerve fiber layer (RNFL) of glaucoma patients: optical coherence tomography (OCT), scanning laser polarimetry (SLP) and confocal scanning laser ophthalmoscopy (CSLO). MATERIALS AND METHODOLOGY 114 eyes of patients with moderate open angle glaucoma underwent spectral dom...
متن کاملComparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma
BACKGROUND We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. MATERIAL/METHODS Study subjects had advanced primary open-angle glaucoma, pre...
متن کاملComparison of Retinal Nerve Fiber Layer Thickness Measurements in Healthy Subjects Using Fourier and Time Domain Optical Coherence Tomography
Purpose. To compare the retinal nerve fiber layer (RNFL) measurements using two different ocular coherence tomography (OCT) devices: Cirrus Fourier domain OCT and Stratus time domain OCT. To analyze reproducibility of Fourier domain measurements in healthy subjects. Methods. One hundred and thirty-two eyes of 132 healthy subjects were scaned on the same day with both instruments, separated by 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic surgery, lasers & imaging retina
دوره 44 6 Suppl شماره
صفحات -
تاریخ انتشار 2013