[Estimation of the effective dose of patient in interventional radiology: study of coronary angiography].
نویسندگان
چکیده
The applications of interventional radiology (IVR) increasingly are being used in clinical examinations, where they tend to extend examination time. In addition, the risk of occupational exposure necessarily is increasing with this technology. In this study, the dose distributions in a sliced acrylic-acid phantom involving the bore for each irradiation condition were measured using a thermoluminescence dosimeter (TLD). Four patterns of set-up for the fluoroscopy unit were chosen as references for the conditions generally used clinically. Exposure also was measured with dose area product (DAP), and we then calculated the entrance skin dose and effective dose for the patient. The results showed that the effective dose was 7.0 mSv to 8.0 mSv at LAO45 degrees and RAO30 degrees; 100 kV, 2.3 mSv to 3.3 mSv at LAO45 degrees and RAO30 degrees; 80 kV. The effective dose is greatly influenced by the setup of fluoroscopy in IVR. The change in DAP is especially influenced. We found that the relation between DAP and effective dose was corrected with the exponential function. The effective doses were not necessarily less than those of other radiation examinations, and increase. When PCI and TAE are repeated many times in IVR, we propose that the effective dose should be taken into consideration together with the skin dose for dose control management.
منابع مشابه
Staff dose assessment from coronary angiography
Background: Interventional cardiology procedures such as coronary angiography (CA) and percutaneous transluminal coronary angiography (PTCA) has been increased recent years. The purpose of this study was to measurement of effective dose to cardiology staffs who operate near the patient and are exposed to non-uniform radiation field due to patient scattered radiation. Materials and Methods: This...
متن کاملAssessment of patients’ entrance skin and effective dose in a mathematical human phantom for the most common interventional radiological examinations
Introduction: Nowadays, we are witnessing an exponential use of interventional radiology techniques in different communities. After CT, interventional techniques are the second factor of increasing patients’ doses in different societies. Measuring patient doses from aforementioned methods has been recommended by many radiation protection professional organizations such as ICRP...
متن کاملComprehensive TLD dosimetry of physicians and patients during interventional angiography procedures to estimate the risk of radiation deterministic effect
Introduction: Interventional angiography procedures are increasingly used today. These techniques require a long time of standing near the patient and x-ray tube which lead to increase the radiation-dose of the staff and interventionists. This may also, in turn, lead to the occurrence of radiation deterministic effects. Since a large number of interventional radiology were perf...
متن کاملBreast Radiation Protection in Coronary Angiography
Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...
متن کاملEffective Dose of Radiation in Diagnostic and Interventional Cardiac Angiography among Pediatrics and Adolescents in Hospitals of Shiraz University of Medical Sciences versus Other Radiology Devices
Background: Cardiac catheterization and angiography are diagnostic and therapeutic imaging modalities that produce the highest X-ray radiation, which might impose lifelong risks to patients. This study aimed to evaluate radiation burden among children and adolescents with congenital heart diseases, who underwent cardiac catheterization and angiography. Then the results were compared with other ...
متن کاملAssessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran
Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nihon Hoshasen Gijutsu Gakkai zasshi
دوره 62 8 شماره
صفحات -
تاریخ انتشار 2006