PURPOSE Bilateral inferior petrosal sinus sampling (IPSS) is a direct method of distinguishing between pituitary and ectopic ACTH secretion. We present unilateral femoral route technique avoiding bilateral femoral venous puncture using two 4F catheters into both sides of IPSS in these obese patients. MATERIALS AND METHODS Unilateral femoral puncture using 9F guiding catheter allowed two 4F catheters which can be introduced in each side of inferior petrosal sinus. To reduce bleeding in the gap between 2 catheters at the diaphragm of the 9F femoral sheath, we introduced a short guidewire provided along with femoral sheath. After removing the 9F sheath after procedure, we applied manual compression as usual. We evaluated any technical difficulty and other complications including the presence of hematoma at the puncture site 1 day and 30 days later. RESULTS Bilateral IPSS by using two 4F catheters in both inferior petrosal sinuses was possible via unilateral femoral route via 9F sheath. There was no technical difficulty introducing 4F catheters into each IPS of both sides. After removing 9F femoral sheath, there was no other complication and no hematoma at the puncture site at 1 day and 30 days later. CONCLUSION Unilateral femoral venous approach with a 9-French sheath can be used in IPSS. This technique allowed to pass two 4F catheters for IPSS at both sides and could avoid unnecessary bilateral femoral puncture in these obese patients without any hematoma formation after the procedure.
منابع مشابه
Anatomy of the junction of the inferior petrosal sinus and the internal jugular vein.
PURPOSE To evaluate the anatomy of the junction of the inferior petrosal sinus and the internal jugular vein. METHODS Using a previously described classification system, we prospectively classified venous anatomy bilaterally in 135 of 136 persons consecutively undergoing inferior petrosal sinus sampling. RESULTS Type IV anatomy, with no anastomosis between the inferior petrosal sinus and th...
متن کاملBilateral sequential inferior petrosal sinus sampling with corticotrophin-releasing hormone stimulation in the diagnosis of Cushing's disease.
OBJECTIVE The demonstration of a central to peripheral ACTH gradient in a hypercortisolaemic patient is diagnostic of Cushing's disease. We tried to determine whether single blood samples for ACTH obtained sequentially from each of the inferior petrosal sinuses following human corticotrophin-releasing hormone (hCRH) stimulation can reliably establish such a gradient. DESIGN Prospective study....
متن کاملAdrenocorticotropic hormone-dependent Cushing's syndrome: sensitivity and specificity of inferior petrosal sinus sampling.
BACKGROUND AND PURPOSE Determining the cause of Cushing's syndrome can be difficult. Bilateral inferior petrosal sinus (IPS) sampling after ovine corticotropin-releasing hormone (oCRH) stimulation is an established technique for the differentiation of pituitary from nonpituitary sources of adrenocorticotropic hormone (ACTH) production. The purpose of this study was to review our experience to d...
متن کاملVenous subarachnoid hemorrhage after inferior petrosal sinus sampling for adrenocorticotropic hormone.
Neurologic complications associated with inferior petrosal sinus sampling for adrenocorticotropic hormone in the diagnosis of Cushing syndrome are rare. Previously reported complications include brain stem infarction and pontine hemorrhage. We report a case of venous subarachnoid hemorrhage with subsequent acute obstructive hydrocephalus occurring during inferior petrosal sinus sampling for Cus...
متن کاملThe role of bilateral inferior petrosal sinus sampling in the diagnostic evaluation of Cushing syndrome.
Bilateral inferior petrosal sinus sampling is the gold standard diagnostic assay in identifying the pituitary source of adrenocorticotropic hormone secretion in Cushing syndrome. The noninvasive assays used in the workup of Cushing syndrome are often misleading or ambiguous, yielding sensitivities of up to only 80%. Inferior petrosal sinus sampling, however, is highly accurate a...