Is TrueFISP a gradient-echo or a spin-echo sequence?
نویسندگان
چکیده
It is commonly accepted that TrueFISP (balanced FFE, FIESTA) belongs to the class of gradient-echo (GRE) sequences. GRE sequences are sensitive to dephasing effects of the transverse magnetization between the excitation pulse and echo acquisition, and phase coherence is only established directly after and before excitation pulses. However, an analysis of the phase evolution of transverse magnetization in a TrueFISP experiment shows very close similarities to the echo formation of a spin-echo (SE) experiment. If dephasing between excitation pulses is below +/-pi, TrueFISP exhibits a nearly complete refocusing of transverse magnetization at TE = TR/2. Only signals acquired before and after TR/2 show an additional T*2 sensitivity.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملMR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence.
MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal ...
متن کاملThe sensitivity of TrueFISP to mesoscopic field inhomogeneities
S. Köhler, J. Maier, K. Hiller, A. Haase, P. M. Jakob Physikalisches Institut, EP5, Wuerzburg, Germany Synopsis The purpose of the present study is to investigate the sensitivity of TrueFISP to mesoscopic field inhomogeneities and to analyse the effect of intravoxel dephasing in TrueFISP sequences compared to conventional gradient echo experiments. Numerical simulations on different off-resonan...
متن کاملNavigator-Gated Whole Heart Coronary MRI with 3D isotropic Double Echo TrueFISP UTE
Introduction Coronary MRA provides a non-invasive approach for the detection of coronary artery disease. Previous works have shown that whole heart 3D radial techniques simplify the scanning procedure with no compromise in image quality [1-4]. Ultra-short Echo Time (UTE) MRI allows for the detection of short T2 components (T2 of the order of 100 μs) in tissue before they have decayed [5, 6]. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 49 2 شماره
صفحات -
تاریخ انتشار 2003