Objective: Safety and efficacy of Ahmed glaucoma valve implantation for the management of uveitis induced glaucoma evaluated on the five dogs with uncontrollable glaucoma. Materials and Methods: Ahmed Glaucoma Valve (AGV®; New World Medical, Rancho Cucamonga, CA, USA) is a flow restrictive, nonobstructive self-regulating valve system. Preoperative ocular evaluation included direct ophthalmoscopy and measurement of the intraocular pressure (IOP). The implant was examined and primed prior to implantation. The selected site of the valve implantation was the superior quadrant between the superior and lateral rectus muscles. A fornix-based incision was made through the conjunectiva and Tenon’s capsule. A pocket is formed by blunt dissection of Tenon’s capsule from the episclera. The body of the implant was inserted into the pocket with the leading edge of the device around 8-10 mm from the limbus. Results: No post-operative complications were detected in the operated eyes except a persistent corneal edema occupied the upper half of the cornea in one case. Hyphaema was very mild and seen only in two cases which resolved quickly two days after surgery. Endoscopical evaluation for the operated eyes revealed a normal ocular fundus with clearly visible optic papilla, tapetum and retinal blood vessels. No evidence of hemorrhage, infection, adhesions or retinal abnormalities was detected. Conclusion: Ahmed glaucoma valve is safe and effective implant for treatment of uveitic glaucoma in dogs. Keywords—Ahmed valve, endoscopy, glaucoma, ocular fundus.
منابع مشابه
Improved Surgical Success of Combined Glaucoma Tube Shunt and Retisert® Implantation in Uveitic Eyes: A Retrospective Study
INTRODUCTION The purpose of this study was to determine whether the outcomes following placement of a fluocinolone acetonide implant (Retisert(®); Bausch & Lomb, Inc.) combined with an Ahmed™ glaucoma valve (New World Medical, Inc.) in eyes with uveitic glaucoma (UG Retisert) were different when compared to an Ahmed valve alone in eyes with uveitic glaucoma or primary open angle glaucoma (UG no...
متن کاملA retrospective study on the outcomes of Ahmed valve versus Ahmed valve combined with fluocinolone implant in uveitic glaucoma.
Purpose To compare the intraocular pressure (IOP) outcomes of Ahmed glaucoma valve (AGV) surgery alone versus AGV with fluocinolone implant in uveitic glaucoma patients. Methods We identified uveitic glaucoma patients with AGV surgery alone and AGV surgery combined with fluocinolone implant from the Massachusetts Eye and Ear Ocular Inflammation Database. Demographic information, visual acuity...
متن کاملUsing Ahmed’s Gonioimplant Valve to Surgical Treatment of Glaucoma in Two Dogs
Case Description- An eleven-year-old Golden retriever male dog (dog I) and a four-year-old neutered Toy Terrier (dog II) were referred to Small Animal Clinic. Dog I was suffered from partial loss of vision and engorgement of episcleral vessels of his right eye and dog II was blind. Intraocular pressure (IOP) of right eye was 37.8 mmHg in dog I and 34.5 and 31.6 mmHg in the right and left...
متن کاملCombined Glaucoma Tube Shunt (Ahmed) and Fluocinolone Acetonide (Retisert™) Implantation Compared to Ahmed Alone in Uveitic Glaucoma
INTRODUCTION Glaucoma is a known complication of uveitis, and may require glaucoma tube shunt implantation for intraocular pressure (IOP) control. The success of glaucoma tube shunt implantation in the setting of a local ocular steroid depot in uveitic glaucoma remains unknown. The purpose of this study was to determine whether patients who underwent combined glaucoma tube shunt (Ahmed) and flu...
متن کاملReview of the Ahmed versus Baerveldt study—5-year treatment outcomes
The results from the tube versus trabeculectomy (TVT) study provided the evidence to support the use of aqueous shunt surgery and its increasing popularity in the world. The Ahmed versus Baerveldt (AVB) study, a randomized controlled study, compared the efficacy and safety between two of the most commonly used glaucoma drainage implants. A significant proportion of the participants had failed t...