Non-invasive assessment of functionally significant coronary stenoses through mathematical analysis of spectral ECG components
نویسندگان
چکیده
OBJECTIVES The aim of this study was to evaluate the accuracy of the Multifunction CardioGram (MCG) in detecting the presence of functionally significant coronary ischaemia. METHODS AND RESULTS This prospective study evaluated the accuracy of the MCG, a new ECG analysis device used to diagnose ischaemic coronary artery disease (CAD). A consecutive 112 participants suspected to have CAD who were scheduled for elective coronary angiography (CAG) from October 2012 to December 2013 were examined. Their predictive values of relevant ischaemia were measured by MCG, standard ECG and Framingham Risk Score (FRS) and compared. Five levels of ischaemia based on CAG findings adjusted by fractional flow reserve (FFR) values and three levels of MCG score of high, borderline or low were used. The MCG (OR=2.67 (1.60 to 4.44), p<0.001) was the only test significantly associated with ischaemia level. The FFR values for individual MCG scores with low, borderline and high were 0.77 (0.70 to 0.86), 0.78 (0.71 to 0.82) and 0.69 (0.65 to 0.77), respectively, p=0.042. A high MCG score had a specificity of 90.4% (87.0% to 93.9%) in model 1 adjusted by FFR≤0.8 threshold and of 87.0% (83.2% to 90.8%) in model 2 adjusted by FFR≤0.75 threshold, and a negative predictive value of 82.5% (78.3% to 86.7%) in model 1 and of 83.8% (79.6% to 87.9%) in model 2 for the prediction of severe ischaemia. CONCLUSIONS The MCG showed high specificity with a high negative predictive value, suggesting that the MCG could be used not only to identify functionally significant ischaemia but to reduce unnecessary CAGs. TRIAL REGISTRATION NUMBER UMIN ID: 000009992.
منابع مشابه
Database Management Expert Program for Integrated Evaluation of Non-Invasive and Invasive Results of Coronary Heart Disease
The coronary angiography giving the morphological data of epicardiac coronary stenoses and non-invasive tests sometimes even together are insufficient for evaluating the functional consequences of the epicardiac coronary stenoses. However, catheterisation allows us to detect the blunting of coronary flow increase during maximal vasodilatation (coronary flow reserve, CFR, e.g. by Doppler flow wi...
متن کاملThe prognostic value of residual coronary stenoses after functionally complete revascularisation.
Fractional flow reserve (FFR) has become the gold standard for functional assessment of coronary artery stenosis. Studies have confirmed the superiority of FFR guided percutaneous coronary intervention (PCI) compared to angiography guided PCI. Due to the high cost of FFR, it is not economically viable for FFR to be incorporated into every routine invasive coronary angiography. As a result, visu...
متن کاملCT coronary angiography vs. invasive coronary angiography in CHD
SCIENTIFIC BACKGROUND Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT) coronary angiography are used in the diagnosis of coronary heart disease (CHD). RESEARCH QUESTIONS The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and leg...
متن کاملNon-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.
AIMS A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND RESULTS A total of 102 patients underwent both conventional and MDCT coronar...
متن کاملCoronary computed tomographic angiography and exercise electrocardiography: a great match or unequal partners?
Coronary computed tomographic angiography (CCTA) is emerging as a powerful non-invasive tool in the diagnosis of coronary artery disease (CAD). However, there is concern that CCTA is being used indiscriminately without sufficient examination of its added value vis-à-vis more established forms of non-invasive testing. With an evergrowing armament of non-invasive tests for the diagnosis and evalu...
متن کامل