Interspinous devices: are they as attractive as they seem? An intermediate-term follow-up

نویسندگان

  • Josh E. Schroeder
  • Leon Kaplan
  • Shimon Barzilay
  • Yair Barzilay
چکیده

STUDY DESIGN  A retrospective cohort of 68 patients who underwent insertion of the DIAM (Medtronic Sofamor Danek, Switzerland) interspinous device (ISD) during 2006-2008 at one medical center. OBJECTIVES  To assess the short- and intermediate-term outcomes and complications associated with ISD. METHODS  Evaluation of files and all patients who underwent insertion of a DIAM ISD was performed. Patients walking distances and pain (visual analog scale score) were compared with data gathered before surgery. Outcome and all complications related to ISD have been identified and analyzed. RESULTS  All 68 patients were available for follow-up. Mean follow-up was 34 months (23-52 months). The average age was 57 (±13) years. Walking distance increased by 890% and patient's pain score improved by 3.27 points on visual analog scale. Twenty-one (32%) of the 68 patients had perioperative or late complications. Nine complications (75%) were unrelated to ISD and included 5 dura tears, 3 wound-related complications, and 1 transient ischemic attack. Spinous process fractures occurred in 5 cases, leading to revision in 2 cases. In total, 7 of the patients required revision surgery. These patients were older, with an average age of 69 years. CONCLUSION  The outcome of patients who had an implantation of the DIAM ISD is good. In this cohort, 6% developed recurrent claudication symptoms in the second postoperative year. In an older population, the combination of softer bone and rigid stenosis increase the risk of spinous process fracture, resulting in failure and leading to revision surgery. Other solutions should be sought for these patients. [Table: see text] The definiton of the different classes of evidence is available on page 55.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term Follow-up (Minimum 5 Years) Study of Single-level Posterior Dynamic Stabilization in Lumbar Degenerative Disease; 'Interspinous U' & 'DIAM'

OBJECTIVES Recently posterior dynamic stabilizations (PDS) are increased in degenerative lumbar disease. But, some previous studies had doubts its long term prognosis. Long term clinical and radiological results of PDS using interspinous device (Interspinous U, DIAM) were analyzed. METHODS We have used the 'interspinous U' and 'DIAM' for patients with lumbar spinal stenosis. We included singl...

متن کامل

سم‌زدایی سریع: مروری بر مزایا و معایب

AbstractObjectives: The purpose of present study was to review the literature for advantages and shortcomings of ultra rapid detoxification. This method often is performed with naloxone and naltrexone with symptoms of withdrawal controlled under general anesthesia or deep sleep. Method: More than 70 full text articles were studied they were looked up in Medline, from 1985 to 2002, using the key...

متن کامل

Interspinous Spacers in the Lumbar Spine

Recently, a new class of spinal devices called interspinous spacers (ISPs) has been introduced. A number of designs have been developed, which vary from non-compressible metallic spacers to compressible cushion-like devices. Following the path of other spinal devices, they are composed of materials ranging from allograft bone, titanium alloy, polyetheretherketone (PEEK), and elastomeric prepara...

متن کامل

Assistive Technology: Use and Service Delivery

As individuals with long-term disabilities and other older adults face declines in health and function, there is a greater need for assistive technology (AT) or assistive devices and environmental interventions (EI) to help them maintain their independence and community participation. These aids can help older adults and individuals with disabilities function in work, home, recreational, and ot...

متن کامل

Surgical treatment of lumbar spinal stenosis with microdecompression and interspinous distraction device insertion. A case series

BACKGROUND Interspinous distraction devices (IPDD) are indicated as stand-alone devices for the treatment of spinal stenosis. The purpose of this study is to evaluate the results of patients undergoing surgery for spinal stenosis with a combination of unilateral microdecompression and interspinous distraction device insertion. METHODS This is a prospective clinical and radiological study of m...