Is it time to retire the CTDI for CT quality assurance and dose optimization?

نویسنده

  • David J Brenner
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimization. For the proposition.

Suggestions for topics suitable for these Point/Counterpoint debates should be addressed to Colin G. Orton, Professor Emeritus, Wayne State University, Detroit: [email protected]. Persons participating in Point/Counterpoint discussions are selected for their knowledge and communicative skill. Their positions for or against a proposition may or may not reflect their personal opinions or the pos...

متن کامل

Optimization of Parameters in 16-slice CT-‌‌scan Protocols for Reduction of the Absorbed Dose

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

متن کامل

Design and manufacturing a CTDI pediatric phantom for CT dosimetry using TLD, ion chambers, and gel dosimetry

Introduction: Nowadays, the demand for CT-scan is increased, and this issue has become a critical subject in radiation protection, because of the risk of cancer especially for children. The quality assurance of CT images is a necessary factor that can effect on children dose. The CT dose index is an important dosimetry index in CT-Scan dosimetry. The purpose of this study is t...

متن کامل

An assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System

Introduction: In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray  examinations and it contributes 34% of the resultant collective dose worldwide. Children are more  sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be  carried out periodically on the CT scanners. The aim of this research was to estimate the effective  ...

متن کامل

Comparison of two different methods for CTDIw calculation in CBCT systems

Introduction: Dental Cone beam CT (CBCT) is an imaging modality which has emerged as a 3D imaging modality of choice for osseous structures in the maxillofacial region. With increased usage of CBCT imaging for diagnosis and treatment planning, it is imperative that stringent dose assessments must be performed for dose estimation to safeguard both the patients and operating staf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 32 10  شماره 

صفحات  -

تاریخ انتشار 2005