In-vitro wear measurement of total knee replacement using tibial polyethylene inserts in combination with ceramic and metallic femoral components under abrasive three body wear conditions

ثبت نشده
چکیده

INTRODUCTION: Due to increased life expectancy at human population the amount of osteoarthritis of the knee joint will increase. The total knee replacement (TKR) is often the only way to achieve analgesia, to establish the joint function and to correct joint deformation. TKR reached a high grade of quality and safety and has become an often used surgical procedure [1]. TKR most often fail due to aseptic implant loosening. In the absence of infection, aseptic loosening may occur due to the biological response of the bone to stress shielding, micro motion or biological loosening due to osteolysis. It is believed that polyethylene (PE) wear debris, generated at the articulating surfaces, leading to osteolysis and loosening of endoprosthesis [2]. Therefore the prior aim is to minimize the generation of wear debris by providing low-wear bearings. Beside wear caused by adhesion, surface damage and wear can also be caused by three body particles. De Baets et al. showed that 42% of the debris left in situ are bone cement particles which can damage the surfaces and induce wear [3]. The objective of this experimental study was to evaluate the wear of the tibial PE insert of the total knee endoprosthesis system Multigen Plus CR with metallic and ceramic femoral components at three body wear situation induced by polymethylmethacrylate (PMMA) and zirconia (ZrO2) particles from bone cement. For gait simulations a knee joint wear simulator according to ISO 14243 were used. Previous experimental studies show less wear of PE/ceramic couplings in comparison to PE/metallic because of the low friction of ceramic surface [4]. Moreover, the incidence of allergic reaction against metallic implant materials increases [5]. Hence, allergic-free implants could improve the long term survival rate of total knee endoprosthesis. Biological inert implants consisting of ceramics could offer an alternative solution to patients with sensitivity to metals [6].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performanc...

متن کامل

Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study

BACKGROUND Most contemporary total disc replacements (TDRs) use conventional orthopaedic bearing couples such as ultrahigh-molecular-weight polyethylene (polyethylene) and cobalt-chromium (CoCr). Cervical total disc replacements incorporating polyetheretherketone (PEEK) bearings (specifically PEEK-on-PEEK bearings) have been previously investigated, but little is known about PEEK-on-ceramic bea...

متن کامل

Knee Simulator Protocol for Testing of Oxidized Zirconium and Cobalt Chrome Femoral Components under Abrasive Conditions

INTRODUCTION: Surfaces of retrieved total knee arthroplasty (TKA) femoral components reveal that roughening often occurs in vivo [1,2]. Many scratches have plowed-up adjacent peaks often with some crosshatching, and appear to be created by abrasive particles, such as bone cement, metal, or bone debris. In vitro studies have shown that scratches, particularly those at an angle to the direction o...

متن کامل

Wear of Highly Cross-linked Polyethylene against Cobalt Chrome and Ceramic Femoral Heads

+*Jennings, L M; *Galvin, A L; *Fisher J +Institute of Medical & Biological Engineering, Leeds, UK [email protected] Introduction There is increasing interest in the coupling of highly cross-linked polyethylene with large diameter heads in the hip, due to the reported lower wear characteristics of highly cross-linked polyethylene compared to conventional polyethylene [1, 2, 3]. Further, ...

متن کامل

Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titanium nitride coatings for artificial knee joints.

Most total knee replacement joints consist of a metal femoral component made from a cobalt-chromium- molybdenum (CoCrMo)-alloy and a tibial component with an ultrahigh molecular weight polyethylene (UHMWPE) bearing surface. Wear of the UHMWPE remains the primary disadvantage of these implants. The allergic potential ascribed to CoCrMo-alloys is a further concern. Other metallic alloys with and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010