Mean Expected Error in Prediction of Total Body Water: A True Accuracy Comparison between Bioimpedance Spectroscopy and Single Frequency Regression Equations

نویسندگان

  • Fernando Seoane
  • Shirin Abtahi
  • Farhad Abtahi
  • Lars Ellegård
  • Gudmundur Johannsson
  • Ingvar Bosaeus
  • Leigh C Ward
چکیده

For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun's prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis.

BACKGROUND The accurate assessment of body fluid volume is important in many clinical situations. Hannan et al. proposed a single-frequency bioimpedance equation (HE) to calculate extracellular water (ECW) and total body water (TBW). There are two equations based on the bioimpedance spectroscopy (BIS) method for the evaluation of body fluid volume: Xitron equations (XE) and body composition spe...

متن کامل

New equations for estimating body cell mass from bioimpedance parallel models in healthy older Germans.

The objectives of this study were to assess for elderly Germans the validity of existing equations for predicting body cell mass (BCM) and to develop from single- and multifrequency bioimpedance (SFBIA, MFBIA) models new prediction equations. In a data-splitting approach, validation and cross-validation were performed in 160 healthy elderly (60- to 90-yr) subjects. BCM was determined using a te...

متن کامل

Total Body Water Changes Using Segmental Bioimpedance in Healthy Population with Similar Anthropometry

Electrical bioimpedance was measured in 7 body segments, and also with the standard right-side method, using 11 electrodes at 6 different frequencies in 8 healthy male subjects with similar anthropometry. Our objective was to determine the capability of segmental bioimpedance measurements to estimate small changes of water on each segment (TWsegi) and total body water (TBW) in comparison with t...

متن کامل

A comparison of bioimpedance methods for detection of body cell mass change in HIV infection.

The maintenance of body cell mass (BCM) is critical for survival in human immunodeficiency virus (HIV) infection. Accuracy of bioimpedance for measuring change (Delta) in intracellular water (ICW), which defines BCM, is uncertain. To evaluate bioimpedance-estimated DeltaBCM, the ICW of 21 weight-losing HIV patients was measured before and after anabolic steroid therapy by dilution (total body w...

متن کامل

Predicting body cell mass with bioimpedance by using theoretical methods: a technological review.

The body cell mass (BCM), defined as intracellular water (ICW), was estimated in 73 healthy men and women by total body potassium (TBK) and by bioimpedance spectroscopy (BIS). In 14 other subjects, extracellular water (ECW) and total body water (TBW) were measured by bromide dilution and deuterium oxide dilution, respectively. For all subjects, impedance spectral data were fit to the Cole model...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015