Context: Since the year 2000, allogeneic tissues utilized for operations in humans in the United States have commonly undergone terminal sterilization with gamma irradiation. Ethylene oxide sterilization of tissues processed for human implantation has been abandoned Objectives: (1) To record the long-term successful experience of a precursor transplantation laboratory in the provision of human bone and fascia sterilized with "cold cycle" ethylene oxide; (2) to report the successful experience of a single neurosurgeon operating in a community hospital using only this bone to fuse and stabilize the lumber spine without instrumentation; (3) to review historic and contemporary scientific evidence for the biologic and biomechanical effects of ethylene oxide gas and gamma irradiation exposure on tissues, along with their virucidal, fungicidal and bactericidal properties for surface and interstitial sterilization. Design: Records from the Western Transplantation Services (WTS) laboratory were scrutinized documenting the 18 years of its existence (1978-1996) as well as the voluminous, carefully preserved records of patient interactions, preoperative, operative, and postoperative records archived over three decades from 321 patients undergoing 339 operations by a single neurosurgeon utilizing 1,135 tricortical iliac crest wedges sterilized with ethylene oxide. Main Outcome Measures: Rates of infection and neoplasia in allograft recipients or in laboratory personnel from preparation and distribution of over 50,000 ethylene oxide sterilized allografts provided by a single processing laboratory; lumbar spine fusion rate and complications attributable to grafts among patients receiving these implants. Results: Over 50,000 allografts distributed from Western Tranplantation Services resulted in no reported infections or neoplasia in any recipient and no neoplasia among technicians processing four tissues with exposure to ethylene oxide. Fusion rate among patients undergoing uninstrumented posterior lumbar interbody fusion (PLIF) with tissues distributed by this laboratory was 96% with no reported infections and no allograft fractures. Complication rate of 4% related to the operation and not the performance of the allografts processed by the laboratory. Conclusions: Ethylene oxide sterilization of allogeneic tissues for human transplantation is a safe, efficacious method and merits reconsideration as a remarkably unique surface and interstitial tissue sterilant that is bactericidal, fungicidal and virucidal without compromise of 1 2 3 Open Access Original Article DOI: 10.7759/cureus.121 How to cite this article Prolo D J., Oklund S K., Borer M (June 06, 2013) Efficacy and Safety of Ethylene Oxide Sterilization of Allogeneic Bone for Human Transplantation: A Forty-Year Experience. Cureus 5(6): e121. DOI 10.7759/cureus.121 biomechanical integrity of grafts at doses achieving these sterilizing effects. Categories: Miscellaneous, General Surgery, Neurosurgery

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone Marrow Transplantation and Medical Tourism at Erciyes University - A Single Center Experience

Medical tourism emerged when people were challenged with high costs and slow service in medical care. As a consequence of these issues, people started to look for medical treatment in other countries. Globalization accelerated the growth of medical tourism. Several “push” and “pull” factors play roles in the motivation of patients to become a medical tourist. This review addresses the different...

متن کامل

Role of Stem Cell Transplantation in the Treatment of Burkitt Lymphoma; A Systematic Review

Background: Burkitt lymphoma is a common subtype of non-Hodgkin lymphoma in children. It has a rapid and aggressive clinical course with frequent involvement of bone marrow and central nervous system. Systemic chemotherapy is the mainstay of the treatment for this malignancy in children. In this systematic review, we discuss autologous and allogeneic hematopoietic stem cell transplantation (HSC...

متن کامل

Mechanical strength of cortical allografts with gamma radiation, in Acta Orthop Belg

versus ethylene oxide (ETO) sterilization on the mechanical strength of cortical bone grafts. Tibias were collected from cadavers of mature goats. Sixty test specimens were randomized into four groups : fresh (no processing), frozen (freezing at –70°C), gamma-irradiated, and ETO-sterilized specimens. Torsion, three-point bending, and compression testing were separately performed with a material...

متن کامل

Allograft transplantation in the knee: tissue regulation, procurement, processing, and sterilization.

Use of musculoskeletal allografts has become increasingly popular, with widespread use among knee surgeons. The advantages and disadvantages of their use have been documented. In the knee, allografts are used for ligament reconstruction, meniscal transplantation, and articular surface reconstruction. The purpose of this review is to present issues surrounding the allograft industry, including r...

متن کامل

Tranexamic Acid in Total Joint Arthroplasty: Efficacy and Safety

  Despite improvements in surgical and anesthetic techniques, total joint arthroplasty (TJA) is still associated with substantial blood loss and postoperative anemia (1). A considerable portion of patients with postoperative anemia require blood transfusion, which has been shown to negatively affect the outcome of TJA and predisposes patients to development of surgical site infection and peripr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015