Application of Near-Infrared Spectroscopy for the Evaluation of Placental Oxygenation

نویسندگان

  • Jun Kakogawa
  • Naohiro Kanayama
چکیده

Aims: As the utero-placental circulation have major impact on the fetus, and the placental function can be critical for determining fetal conditions, the placental oxygenation status was investigated. Methods: Near-infrared spectroscopy (NIRS) is a non-invasive technique used for the evaluation of regional tissue oxygenation in a number of organs. The trans-abdominal NIRS was developed as a non-invasive technique for monitoring placental oxygenation, which was evaluated by the ratio of oxygenated hemoglobin to total hemoglobin (%) (tissue oxygenation index ,TOI) values. The near-infrared light was confirmed to reach the placenta using the NIRS probe with an inter-optode distance of 4.5 cm and the NIRO apparatus (Hamamatsu Photonics, Hamamatsu, Japan). Results: Placental TOI values in pregnant women with pregnancy-induced hypertension and intrauterine fetal growth restriction were significantly higher than those of pregnant women without complications, although there were no differences of TOI values between the women with threatened preterm delivery and those without complications. Conclusion: Non-invasive monitoring of placental tissue oxygenation assessed by NIRS for the study of utero-placental function may have a high potential for clinical application, particularly in prenatal management.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012