The ongoing search for simplifying fractional flow reserve assessment: the role of contrast medium

نویسندگان

  • Pio Cialdella
  • Domenico D’Amario
  • Antonio Maria Leone
چکیده

The current knowledge on the pathophysiology of coronary artery stenosis stems from the seminal studies by Lance Gould, who first described the pressure/flow/ resistance characteristics, defining the coronary flow reserve as the ratio between hyperaemic and basal flow [1]. From the beginning it was clear, indeed, that this technique had several major limitations, and therefore the concept of fractional flow reserve (FFR) was introduced. The FFR was defined as the ratio of two flows, calculated from two pressure values, obtained during maximal hyperaemia [2]. Consequently, the achievement of hyperaemia is the crucial prerequisite to assess FFR correctly. In this regard, the administration of intravenous (i.v.) adenosine is still considered the gold standard. Even so, the correct achievement of maximal hyperaemia has been acknowledged as one of the major challenges of this technique, leading to significant FFR underutiliza-tion worldwide [3]. Indeed, i.v. adenosine is perceived as a time-consuming , relatively expensive tool, relatively uncomfortable for the patient. In order to circumvent, at least partially, these limitations, the vast majority of interventional cardiolo-gists prefers the intracoronary (i.c.) route of administration , even in highly skilled centres [4]. However, the most favourable dose of adenosine to be administered is still a matter of debate. Our group has previously demonstrated that only a high dose bolus of 600 µg of i.c. adenosine has an effect on FFR comparable to the i.v. route, but this is achieved at a higher risk of atrioventricular (AV) block [5]. For this reason, we suggested to perform increasing boli of i.c. adenosine up to 600 µg, switching to the i.v. route in case of AV block. Recently, Adjedj et al. suggested that the best combination of hyperaemia and safety could be achieved by injecting 200 µg of adenosine in the left coronary artery (LCA) and 100 µg in the right [6]. However , these doses are still associated with a significant rate of AV block without reaching maximal hyperaemia. If adenosine still has some drawbacks, other potentially valuable vasodilator agents do not perform better [7]. For these reasons, adenosine-free pressure-derived indices were proposed over the last years. In 2010 Mamas et al. proposed the simple resting Pd/Pa value to predict positivity of FFR. Pd/Pa was demonstrated to be significantly correlated with FFR and relatively accurate in predicting a positive FFR with an area under the curve (AUC) of 0.86, and the authors concluded that for values lower than 0.87 …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physiological basis of clinically used coronary hemodynamic indices.

In deriving clinically used hemodynamic indices such as fractional flow reserve and coronary flow velocity reserve, simplified models of the coronary circulation are used. In particular, myocardial resistance is assumed to be independent of factors such as heart contraction and driving pressure. These simplifying assumptions are not always justified. In this review we focus on distensibility of...

متن کامل

Efficacy of coronary fractional flow reserve using contrast medium compared to adenosine

INTRODUCTION Coronary fractional flow reserve (FFR) is recommended as the gold standard method in evaluating intermediate coronary stenoses. However, there are significant debates concerning the agents and the timing of the measurement. AIM To compare the contrast medium induced Pd/Pa ratio (CMR) with the FFR. MATERIAL AND METHODS We enrolled 28 consecutive patients with 34 intermediate les...

متن کامل

Repair of all the components of the syndrome of aortic regurgitation and VSD.

Heyndrickx GR. Intracoronary and intravenous adenosine 50-triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans. Circulation 2003;107:1877–1883. 21. Pijls N, van Son J, Kirkeeide R, De Bruyne B, Gould K. Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenos...

متن کامل

Rapid exchange ultra-thin microcatheter using fibre-optic sensing technology for measurement of intracoronary fractional flow reserve.

AIMS The present report describes a novel coronary fractional flow reserve (FFR) system which allows FFR assessment using a rapid exchange microcatheter (RXi). METHODS AND RESULTS The RXi microcatheter is compatible with standard 0.014" coronary guidewires facilitating lesion negotiation and FFR assessment in a wide range of coronary anatomies. In case of serial lesions, a microcatheter would...

متن کامل

Comparative analysis of the effects of monetary and government financial expenditures shocks in the context of fractional and full reserve banking in Iran: DSGE approach

The present study aims to investigate the effects of monetary and financial shocks on macroeconomic variables in fractional and full reserve banking conditions. To this end, two stochastic dynamic general equilibrium models have been designed in terms of the realities of Iran's economy and then the effects of shocks have been studied. After determining the input values ​​of the model and estima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016