Correction of phase offset errors in cardiovascular magnetic resonance using background subtraction from stationary tissue

نویسندگان

  • Nilanjana Misra
  • Amee M Shah
  • Wyman W Lai
چکیده

Introduction Phase offset errors from local eddy currents can lead to significant errors in flow assessment on clinical cardiovascular magnetic resonance (CMR) examinations. Phantom correction for phase contrast (PC) errors appears to improve accuracy in flow assessment, but requires additional time and is not free from technical limitations. Background subtraction using a region of stationary tissue has been proposed as an alternative method for the correction of phase offset errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Baseline correction of phase contrast images improves quantification of blood flow in the great vessels.

PURPOSE Phase-contrast Cardiovascular Magnetic Resonance Imaging (CMR) generally requires the analysis of stationary tissue adjacent to a blood vessel to serve as a baseline reference for zero velocity. However, for the heart and great vessels, there is often no stationary tissue immediately adjacent to the vessel. Consequently, uncorrected velocity offsets may introduce substantial errors in f...

متن کامل

Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements

AIMS Cardiovascular magnetic resonance (CMR) allows non-invasive phase contrast measurements of flow through planes transecting large vessels. However, some clinically valuable applications are highly sensitive to errors caused by small offsets of measured velocities if these are not adequately corrected, for example by the use of static tissue or static phantom correction of the offset error. ...

متن کامل

A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors

BACKGROUND Phase-contrast velocity images often contain a background or baseline offset error, which adds an unknown offset to the measured velocities. For accurate flow measurements, this offset must be shown negligible or corrected. Some correction techniques depend on replicating the clinical flow acquisition using a uniform stationary phantom, in order to measure the baseline offset at the ...

متن کامل

Baseline correction of phase-contrast images in congenital cardiovascular magnetic resonance

BACKGROUND One potential source of error in phase contrast (PC) congenital CMR flow measurements is caused by phase offsets due to local non-compensated eddy currents. Phantom correction of these phase offset errors has been shown to result in more accurate measurements of blood flow in adults with structurally normal hearts. We report the effect of phantom correction on PC flow measurements at...

متن کامل

Analysis of temperature dependence of background phase errors in phase-contrast cardiovascular magnetic resonance

BACKGROUND The accuracy of phase-contrast cardiovascular magnetic resonance (PC-CMR) can be compromised by background phase errors. It is the objective of the present work to provide an analysis of the temperature dependence of background phase errors in PC-CMR by means of gradient mount temperature sensing and magnetic field monitoring. METHODS Background phase errors were measured for vario...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011