Focal femoral osteolysis after revision hip replacement with a cannulated, hydroxyapatite-coated long-stemmed femoral component: a new route for particulate wear debris.
نویسندگان
چکیده
We describe a case of symptomatic focal femoral osteolysis around a screw hole distal to the hydroxyapatite-coated portion of a cannulated femoral component in a revision hip replacement. No locking screw had been inserted into this, the most proximal of the three distal holes for locking screws. The presence of polyethylene wear debris in the tissue excised from the lesion suggested that it had passed through the cannulated portion of the stem and out of the proximal unfilled distal locking hole, initiating an osteolytic reaction in an otherwise well-fixed stem. This case highlights an important design characteristic of such cannulated, uncemented femoral components. We recommend that the proximal aperture of these cannulated stems be occluded at implantation.
منابع مشابه
The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem
PURPOSE To evaluate the clinical and radiological results, as well as the survival rate, associated with total hip arthroplasty using a hydroxyapatite (HA)-coated anatomical femoral stem at a follow-up of ≥12 years. MATERIALS AND METHODS From April 1992 to May 1997, 86 patients (102 hips) underwent total hip arthroplasty with a HA-coated ABG I (Anatomical Benoist Giraud; Howmedica) hip prosth...
متن کاملLong-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study.
Between 1986 and 1991 we implanted 331 consecutive Furlong hydroxyapatite-coated femoral components of a total hip replacement in 291 patients. A cemented acetabular prosthesis was used in 217 hips and a hydroxyapatite-coated component in 114. We describe the long-term clinical and radiological survival of the femoral component at a mean follow-up of 17.5 years (15 to 21). Only two patients (0....
متن کاملResults of uncemented porous-coated anatomic total hip replacement.
We reviewed a consecutive series of 241 uncemented, porous-coated anatomic (PCA) hip replacements at an average follow-up of five years (2 to 9). Of these, 32 had failed (13%), 26 at the acetabular component (11%) and six at the femoral component (2%). Acetabular failure was associated with local osteolysis and excessive polyethylene wear in 20 cases: in these histological examination showed gi...
متن کاملHydroxyapatite-ceramic-coated femoral stems in revision hip surgery.
We describe the clinical and radiological results of 120 consecutive revision hip replacements in 107 patients, using the JRI Furlong hydroxyapatite-ceramic-coated femoral component. The mean age of the patients at operation was 71 years (36 to 92) and the mean length of follow-up 8.0 years (5.0 to 12.4). We included patients on whom previous revision hip surgery had taken place. The patients w...
متن کاملA conservative femoral replacement for total hip arthroplasty. A prospective study.
Between 1985 and 1993, 146 patients (162 hips) had total hip replacement (THR) using a conservative uncemented femoral component. The mean age of the patients was 50.8 years and the mean follow-up was 6.2 years (2 to 13). One patient was lost to follow-up, one died within two years of surgery and one had a revision procedure after a fracture sustained in a road-traffic accident. For the remaini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 90 4 شماره
صفحات -
تاریخ انتشار 2008