Prolonged high-pressure is required for optimal stent deployment as assessed by optical coherence tomography.
نویسندگان
چکیده
AIMS Optimizing stent deployment is important for both acute- and long-term outcomes. High-pressure balloon inflation is the standard for coronary stent implantation. However, there is no standardized inflation protocol. We hypothesized that prolonged high-pressure balloon inflation until stabilization of inflation pressure is superior to a rapid inflation/deflation sequence for both stent expansion and strut apposition. METHODS AND RESULTS A high-pressure rapid inflation/deflation sequence was deployed followed by angiography to assure no residual stenosis. Optical coherence tomography (OCT) was then performed followed by prolonged inflation until balloon pressure was stabilized for 30 sec using the same balloon at the same pressure as the rapid sequence. A second OCT run was then done. Thirteen thousand nine hundred thirteen stent struts were evaluated by OCT in 12 patients undergoing successful stenting. Stent expansion improved with prolonged (206 ± 115 sec) vs. rapid (28 ± 17 sec) inflation for both minimal stent diameter (3.0 ± 0.5 vs. 2.75 ± 0.44 mm, P < 0.0001) and area (7.83 ± 2.45 vs. 6.63 ± 1.85 mm(2) , P = 0.0003). The number of malapposed struts decreased (45 ± 41 vs. 88 ± 75, P = 0.005) as did the maximal malapposed strut distance (0.31 ± 0.2 vs. 0.43 ± 0.2 mm, P = 0.0001). Factors related to strut malapposition after rapid inflation included localized asymmetry in 67%, stent underexpansion in 75%, and stent undersizing in 67%. CONCLUSIONS These data demonstrate that prolonged inflation is superior to a rapid inflation/deflation technique for both stent expansion and strut apposition. We recommend for routine stent deployment a prolonged inflation protocol as described above to optimize stent deployment.
منابع مشابه
Suboptimal stent deployment is associated with subacute stent thrombosis: optical coherence tomography insights from a multicenter matched study. From the CLI Foundation investigators: the CLI-THRO study.
BACKGROUND Acute or subacute stent thrombosis (ST) is a well-described complication usually causing acute coronary syndromes and, in the worst case scenario, sudden cardiac death. In this study, we aimed at exploring the potential role of optical coherence tomography (OCT) in the understanding of the mechanism of ST. METHODS Twenty-one consecutive patients, after acute coronary syndromes due ...
متن کاملOptical coherence tomography findings after longitudinal ablation for an underexpanded stent in a heavily calcified lesion: a case report
BACKGROUND Heavy coronary artery calcification is responsible for stent underexpansion, which is associated with increased in-stent restenosis. Here we report a case in which optical coherence tomography (OCT) demonstrated that the metal component of an underexpanded stent previously implanted in a heavy calcified lesion had been completely removed after ablation with rotational atherectomy. ...
متن کاملSpeckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images
Introduction One of the most important pre-processing steps in optical coherence tomography (OCT) is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on ...
متن کاملImpact of frequency-domain optical coherence tomography guidance for optimal coronary stent implantation in comparison with intravascular ultrasound guidance.
BACKGROUND Frequency-domain optical coherence tomography (FD-OCT) is a novel, high resolution intravascular imaging modality. Intravascular ultrasound (IVUS) is a widely used conventional imaging modality for achieving optimal stent deployment. The aim of this study was to evaluate the impact of FD-OCT guidance for coronary stent implantation compared with IVUS guidance. METHODS AND RESULTS A...
متن کاملOptical coherence tomography.
Case presentation: A 56-year-old man presented to the hospital with chest pain and a non–ST-segment elevation myocardial infarction. Thrombotic plaque rupture in the left anterior descending coronary artery was treated with an everolimus-eluting stent. After stent deployment, angiography demonstrated the presence of a hazy opacity at the distal edge of the stent, and there was concern about a p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
دوره 83 4 شماره
صفحات -
تاریخ انتشار 2014