Tidal breathing patterns derived from structured light plethysmography in COPD patients compared with healthy subjects

نویسندگان

  • Shayan Motamedi-Fakhr
  • Rachel C Wilson
  • Richard Iles
چکیده

PURPOSE Differences in tidal breathing patterns have been reported between patients with chronic obstructive pulmonary disease (COPD) and healthy individuals using traditional measurement techniques. This feasibility study examined whether structured light plethysmography (SLP) - a noncontact, light-based technique - could also detect differences in tidal breathing patterns between patients with COPD and healthy subjects. PATIENTS AND METHODS A 5 min period of tidal (quiet) breathing was recorded in each patient with COPD (n=31) and each healthy subject (n=31), matched for age, body mass index, and sex. For every participant, the median and interquartile range (IQR; denoting within-subject variability) of 12 tidal breathing parameters were calculated. Individual data were then combined by cohort and summarized by its median and IQR. RESULTS After correction for multiple comparisons, inspiratory time (median tI) and its variability (IQR of tI) were lower in patients with COPD (p<0.001 and p<0.01, respectively) as were ratios derived from tI (tI/tE and tI/tTot, both p<0.01) and their variability (p<0.01 and p<0.05, respectively). IE50SLP (the ratio of inspiratory to expiratory flow at 50% tidal volume calculated from the SLP signal) was higher (p<0.001) in COPD while SLP-derived time to reach peak tidal expiratory flow over expiratory time (median tPTEFSLP/tE) was shorter (p<0.01) and considerably less variable (p<0.001). Thoraco-abdominal asynchrony was increased (p<0.05) in COPD. CONCLUSION These early observations suggest that, like traditional techniques, SLP is able to detect different breathing patterns in COPD patients compared with subjects with no respiratory disease. This provides support for further investigation into the potential uses of SLP in assessing clinical conditions and interventions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring Ventilatory Activity with Structured Light Plethysmography (SLP) Reduces Instrumental Observer Effect and Preserves Tidal Breathing Variability in Healthy and COPD

The use of a mouthpiece to measure ventilatory flow with a pneumotachograph (PNT) introduces a major perturbation to breathing ("instrumental/observer effect") and suffices to modify the respiratory behavior. Structured light plethysmography (SLP) is a non-contact method of assessment of breathing pattern during tidal breathing. Firstly, we validated the SLP measurements by comparing timing com...

متن کامل

Evaluation of the agreement of tidal breathing parameters measured simultaneously using pneumotachography and structured light plethysmography

Structured light plethysmography (SLP) is a noncontact, noninvasive, respiratory measurement technique, which uses a structured pattern of light and two cameras to track displacement of the thoraco-abdominal wall during tidal breathing. The primary objective of this study was to examine agreement between tidal breathing parameters measured simultaneously for 45 sec using pneumotachography and S...

متن کامل

Tidal breathing parameters measured using structured light plethysmography in healthy children and those with asthma before and after bronchodilator

Structured light plethysmography (SLP) is a light-based, noncontact technique that measures tidal breathing by monitoring displacements of the thoracoabdominal (TA) wall. We used SLP to measure tidal breathing parameters and their within-subject variability (v) in 30 children aged 7-16 years with asthma and abnormal spirometry (forced expiratory volume in 1 sec [FEV1] <80% predicted) during a r...

متن کامل

Relationship between spontaneous expiratory flow-volume curve pattern and air-flow obstruction in elderly COPD patients.

BACKGROUND Assessment of the degree of air-flow obstruction is important for determining the treatment strategy in COPD patients. However, in some elderly COPD patients, measuring FVC is impossible because of cognitive dysfunction or severe dyspnea. In such patients a simple test of airways obstruction requiring only a short run of tidal breathing would be useful. We studied whether the spontan...

متن کامل

Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.

STUDY OBJECTIVE To assess the accuracy of the respiratory inductive plethysmography in the measurement of PEEP-induced changes in end-expiratory lung volume during mechanical ventilation and its accuracy and stability in the measurement of ventilation during controlled mechanical ventilation and spontaneous breathing. DESIGN An open comparison between two methods using a criterion standard. E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017