Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study.

نویسندگان

  • M Gross
  • I Abramovich
  • E I Weiss
چکیده

Microleakage can occur at the abutment-implant (A-I) interface in osseointegrated implants and may cause malodor and inflammation of peri-implant tissues. The degree of microleakage at the A-I interface of 5 implant systems was comparatively assessed at varying closing torques. Using colored tracing probes driven by a 2-atm pressure system, the interface microleakage of Brånemark, Sulzer Calcitek, 3i, ITI, and Steri-Oss implants was determined spectrophotometrically. Microleakage through the A-I interface occurred in all systems, with variability between systems, samples, and closing torques. As closing torque increased from 10 Ncm to 20 Ncm to manufacturers' recommended closing torques, microleakage decreased significantly (P < .005) for all systems. Analysis of variance showed significant interaction between closing torques and the time course of microleakage, and between systems and the time course of microleakage (P < .001). The results indicate that fluids and small molecules are capable of passing through the interface of all the A-I assemblies studied. Presumably in an in situ situation, fluids containing bacterial byproducts and nutrients required for bacterial growth may pass through the interface gap, contributing in part to clinically observed malodor and peri-implantitis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Analysis of implant/abutment marginal fitting

The success rate of osseointegrated implants is reported to be above 90%. Despite of the knowledge of the mechanisms of osseointegration, some faults still occur at implants systems. Recent researches assign those faults mainly to patient’s prosthetic rehabilitation. The misfit at abutment-implant interface and the missing of a passive adaptation between the prosthesis and the abutment can lead...

متن کامل

Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

متن کامل

Comparative study of two different implants with hexogonal connection on the amount of bacteria accumulated at the implant platform site: An in-vivo study

Background and Aims: Nowadays, the best choice for replacing missing teeth are dental implants, however, failure is not unexpected. One of the factors that plays an important role in the implant failure is bacterial microleakage which could cause biological complication. The aim of this study was to compare the bacterial microleakage between the two types of implants. Materials and Methods:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 1999