The use of porous polyethylene (Medpor) lower eyelid spacers in lid heightening and stabilisation.
نویسندگان
چکیده
BACKGROUND/AIMS The management of lower eyelid retraction can be challenging, and established techniques to correct it are not always successful. Previous reports have suggested a role for the ultrathin high density porous polyethylene lower eyelid spacer (Medpor LES) in such patients. The authors report the experience of three surgeons implanting Medpor LES over 1 year, and ascertain whether such implants are a safe and effective alternative to autogenous spacers. METHODS A prospective, interventional, non-comparative case series of consecutive patients. Surgical indications for Medpor LES were noted. Preoperative and postoperative lower marginal reflex distance (L-MRD), vertical palpebral aperture (PA), lagophthalmos, and scleral show inferior to the limbus (LSS) were recorded, together with major and minor complications. RESULTS 32 patients (35 eyelids) had a Medpor LES inserted, 22/32 under local anaesthetic, and nine with adjunctive procedures. Mean follow up was 22 months (range 15-28 months). The Medpor LES was effective in reducing the palpebral aperture (p<0.001) and lagophthalmos (p = 0.04) and raising the lower eyelid height by reducing both L-MRD (p = 0.006) and LSS (p<0.001). However there were major complications in 7/32 patients and minor complications in 8/32, most requiring further surgery. Final outcome was good in 24/35 eyelids and satisfactory in 5/35. CONCLUSIONS Despite a good or satisfactory final outcome in the majority of patients, the value of this technique is limited by complications, and should be reserved for those unsuitable for safer techniques.
منابع مشابه
Safety and Biocompatibility of a New High-Density Polyethylene-Based Spherical Integrated Porous Orbital Implant: An Experimental Study in Rabbits
Purpose. To evaluate clinically and histologically the safety and biocompatibility of a new HDPE-based spherical porous orbital implants in rabbits. Methods. MEDPOR (Porex Surgical, Inc., Fairburn, GA, USA), OCULFIT I, and OCULFIT II (AJL Ophthalmic S.A., Vitoria, Spain) implants were implanted in eviscerated rabbis. Animals were randomly divided into 6 groups (n = 4 each) according to the 3 im...
متن کاملSix cases of bacterial infection in porous orbital implants.
BACKGROUND We present 6 cases of bacterial infection that developed after porous orbital implant surgery. CASES Five patients with hydroxyapatite implants showed lid swelling, discharge, and suppurative granuloma 14 days to 3 years after surgery. The hydroxyapatite implants were removed 14 days to 41 months postoperatively, and synthetic porous polyethylene orbital implants were inserted. Thi...
متن کاملUse of porous high-density polyethylene grafts in open rhinoplasty: no infectious complication seen in spreader and dorsal grafts
OBJECTIVE The aim of this study is to use porous high-density polyethylene grafts (Medpor) in open rhinoplasty and then assess complication rate and aesthetic outcomes. METHODS In a prospective cohort study, we performed open rhinoplasty and employed Medpor as rhinoplasty grafts. Then we compared their complication rate. RESULTS In a total of 64 patients, 84 Medpor grafts--8 dorsal grafts, ...
متن کاملبررسی شش ماهه ضایعات خوشخیم پلکها
Introduction: Benign eyelid lesions are classified to infectious, inflammatory and tumoral lesions. The various number of these lesions is due to unique eyelid anatomical structure. Some lesions are simple and do not need any treatment but sometimes patients refer to ophthalmologists due to beauty or problems such as pain, swelling. The aim of our study is to investigate and compare the relativ...
متن کاملMaxillary bone defect reconstruction using porous polyethylene implants.
PURPOSE The aim of this study was to evaluate the bone repair process in the maxillary sinus in monkeys treated with high-density porous polyethylene (Medpor) METHODS Four capuchin monkeys (Cebus apella) were submitted to bilateral horizontal osteotomies in the anterior wall of the maxillary sinus and divided into 2 groups: control group, left side with no implants, and porous polyethylene gr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 88 9 شماره
صفحات -
تاریخ انتشار 2004