Radial displacement of red blood cells during hemodilution and the effect on arteriolar oxygen profile.

نویسندگان

  • Juan Carlos Briceño
  • Pedro Cabrales
  • Amy G Tsai
  • Marcos Intaglietta
چکیده

In this study, we assessed the magnitude of the erratic deviations in the radial position of red blood cells (RBCs) in the laminar flow regime of arterioles in a hamster window preparation and the intraluminal Po(2) profile to determine whether this variability affects the intraluminal distribution of oxygen in conditions of normal hematocrit and hemodilution. A gated image intensifier was used to visualize fluorescently labeled RBCs in tracer quantities and obtain multiple measurements of RBC radial and longitudinal positions at time intervals on the order of 5 ms within single arterioles (diameter range 40-95 microm). RBCs in the velocity range of 0.3-14 mm/s exhibit a mean coefficient of variation of velocity of 16.9 +/- 10.5% and a SD of the radial position of 1.98 +/- 0.98 microm. Both quantities were inversely related to hematocrit, and the former was significantly lowered by hemodilution. Our experimental results presented very similar values and shape compared with the intraluminal oxygen profile derived theoretically for normal hematocrit, suggesting that shear-augmented diffusion due to the measured radial displacement of RBCs did not significantly affect oxygen diffusion from blood into the arteriolar vessel wall. Po(2) profiles in the arterioles assumed an increasingly parabolic configuration with increasing levels of hemodilution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Redistribution of red blood cell flow in microcirculatory networks by hemodilution.

The effect of isovolemic hemodilution on red blood cell flow distribution was studied in complete self-contained microvessel networks of the rat mesentery. Hematocrit, diameter, and length of all vessel segments as well as the topological structure were determined in control networks (systemic hematocrit, 0.54) and after hemodilution (systemic hematocrit, 0.30). Hemodilution was performed by ex...

متن کامل

Effect of hemodilution on RBC velocity, supply rate, and hematocrit in the cerebral capillary network.

The effect of isovolemic hemodilution on the circulation of red blood cells (RBCs) in the cerebrocortical capillary network was studied by intravital videomicroscopy with use of a closed-cranial-window technique in the rat. Velocity and supply rate of RBCs were measured by tracking the movement and counting the number of fluorescently labeled cells. Arterial blood was withdrawn in increments of...

متن کامل

Hyperoxia in extreme hemodilution.

Intraoperative surgical blood loss is initially replaced by infusion of red cell-free, cristalloidal or colloidal solutions. When normovolemia is maintained the ensuing dilutional anemia is compensated by an increase of cardiac output and of arterial oxygen extraction. In the ideal case, a surgical blood loss can entirely be 'bridged' without transfusion by intraoperative normovolemic hemodilut...

متن کامل

Oxygen transport by low and normal oxygen affinity hemoglobin vesicles in extreme hemodilution.

The oxygen transport capacity of phospholipid vesicles encapsulating purified Hb (HbV) produced with a Po(2) at which Hb is 50% saturated (P 50 ) of 8 (HbV(8)) and 29 mmHg (HbV(29)) was investigated in the hamster chamber window model by using microvascular measurements to determine oxygen delivery during extreme hemodilution. Two isovolemic hemodilution steps were performed with 5% recombinant...

متن کامل

Oxygen release from arterioles with normal flow and no-flow conditions.

The rate of oxygen release from arterioles ( approximately 55 microm diameter) was measured in the hamster window chamber model during flow and no-flow conditions. Flow was stopped by microvascular transcutaneous occlusion using a glass pipette held by a manipulator. The reduction of the intra-arteriolar oxygen tension (Po2) was measured by the phosphorescence quenching of preinfused Pd-porphyr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 286 3  شماره 

صفحات  -

تاریخ انتشار 2004