High Temperature Integrated and Flexible Ultrasonic Transducers for NDT

نویسندگان

  • M. KOBAYASHI
  • C.-K. JEN
  • K.-T. WU
چکیده

Integrated (IUTs) and flexible ultrasonic transducers (FUTs) are presented for NDT at high temperatures. These transducers are made of sol-gel sprayed piezoelectric thick (> 40μm) ceramic films. The ceramic materials are lead-zirconate-titanate, bismuth titanate and lithium niobate which are for thickness measurement up to 150°C, 400°C and 800°C, respectively. The IUT can be also deposited onto one end of a long ultrasonic delay line to perform non-destructive testing at the other end at even higher temperatures. FUTs made of bismuth titanate films onto thin stainless steel foils are also used for thickness measurements at 300°C with a high temperature couplant sandwiched between the FUT and a steel substrate. All experiments at high temperatures were performed in pulse-echo and ultrasonic echoes with signal to noise ratios above 20dB were obtained. The centre operation frequencies of both IUTs and FUTs range from 4.4MHz to 10.7MHz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Temperature Flexible Ultrasonic Transducers for Structural Health Monitoring and Ndt

Flexible ultrasonic transducers (FUTs) consisting of a 75 μm thick metal membrane, a piezoelectric composite with a thickness larger than 85 μm and a top electrode were developed for structural health monitoring (SHM) and non-destructive testing (NDT) applications. The piezoelectric films were made by a sol-gel spray technique. Its ultrasonic performance in terms of signal strength is at least ...

متن کامل

Integrated and Flexible High Temperature Ultrasonic Transducers

Thick (> 40μm) ceramic films as piezoelectric ultrasonic transducers (UTs) have been successfully deposited on metallic and graphite/epoxy composite substrates by a spray technique. The characteristics of these UTs are that they (1) can be integrated directly onto the desired planar or curved substrates; (2) may not need couplant; (3) can operate in the transmission and pulse/echo modes with a ...

متن کامل

Mn-Doped CaBi4Ti4O15/Pb(Zr,Ti)O3 Ultrasonic Transducers for Continuous Monitoring at Elevated Temperatures

Continuous ultrasonic in-situ monitoring for industrial applications is difficult owing to the high operating temperatures in industrial fields. It is expected that ultrasonic transducers consisting of a CaBi₄Ti₄O15(CBT)/Pb(Zr,Ti)O₃(PZT) sol-gel composite could be one solution for ultrasonic nondestructive testing (NDT) above 500 °C because no couplant is required and CBT has a high Curie tempe...

متن کامل

1 Mn - doped CaBi 4 Ti 4 O 15 / Pb ( Zr , Ti ) O 3 Ultrasonic 2 Transducers for Continuous Monitoring at Elevated 3 Temperatures 4

Continuous ultrasonic in-situ monitoring for industrial applications is difficult owing to 11 the high operating temperatures in industrial fields. It is expected that ultrasonic transducers 12 consisting of CaBi4Ti4O15(CBT)/Pb(Zr,Ti)O3(PZT) sol-gel composite could be one solution for 13 ultrasonic nondestructive testing (NDT) above 500 °C because no couplant is required and CBT has 14 a high C...

متن کامل

Development of a Novel Transparent Flexible Capacitive Micromachined Ultrasonic Transducer

This paper presents the world's first transparent flexible capacitive micromachined ultrasonic transducer (CMUT) that was fabricated through a roll-lamination technique. This polymer-based CMUT has advantages of transparency, flexibility, and non-contacting detection which provide unique functions in display panel applications. Comprising an indium tin oxide-polyethylene terephthalate (ITO-PET)...