Comparison of microtensile bond strength to enamel and dentin of human, bovine, and porcine teeth.

نویسندگان

  • André F Reis
  • Marcelo Giannini
  • Alessandro Kavaguchi
  • Carlos José Soares
  • Sérgio R P Line
چکیده

PURPOSE To determine the bond strengths promoted by an adhesive system to human, bovine, and porcine enamel and dentin, and compare their etched micromorphology by scanning electron microscopy. MATERIALS AND METHODS Thirty sound freshly extracted teeth were used in this study: ten human third molars, ten bovine incisors, and ten porcine molars. The crowns of human (H), bovine (B), and porcine (P) teeth were ground with 600-grit SiC paper to expose either enamel (E) or mid-depth dentin (D) surfaces. After application of the adhesive resin, composite crowns approximately 8 mm high were built up with TPH Spectrum composite. After 24 h of water storage, specimens were serially sectioned in the buccal-lingual direction to obtain 0.8 mm slabs, which were trimmed to an hourglass shape of approximately 0.8 mm2 at the bonded interface. Specimens were tested in tension in a universal testing machine (0.5 mm/min). Results were statistically analyzed with ANOVA and Tukey's test at the 95% confidence level. RESULTS Tukey's test showed significant differences between bond strengths obtained on enamel and dentin (p < 0.05). However, there were no statistically significant differences in microTBS between human, bovine, and porcine teeth. SEM observations revealed a similar dentinal morphology for the three species. However, porcine enamel specimens presented a very different distribution of enamel prisms. CONCLUSION Bovine teeth proved to be possible substitutes for human teeth in either dentin or enamel bond testing. However, even though porcine teeth provided enamel and dentin bond strengths similar to human and bovine teeth, enamel morphology presented a very different configuration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin

Microtensile bond strength of clearfil SE bond to caries-affected dentin and normal dentin Dr. A. Ghasemi* - Dr. M. Bargrizan** - Dr. M. Mahmoodi*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Pedodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. ***...

متن کامل

بررسی اثر استفاده مجدد از میکروبراش بر استحکام باند ریزکششی ادهزیو به عاج

Background and Aims: Re-application of microbrush may affect the micro tensile bond strength of adhesives to dentin. The aim of this study was to evaluate the effect of re-application of microbrushes on the micro tensile bond strength of an adhesive to dentin.Materials and Methods: Thirty freshly extracted molars teeth were collected and enamel of occlusal surface were removed to expose superfi...

متن کامل

Influence of Air Abrasion and Sonic Technique on Microtensile Bond Strength of One-Step Self-Etch Adhesive on Human Dentin

The purpose of this in vitro study was to evaluate the microtensile bond strength of one-step self-etch adhesive to human dentin surface modified with air abrasion and sonic technique and to assess the morphological characteristics of the pretreated dentin surface. The occlusal enamel was removed to obtain a flat dentin surface for thirty-six human molar teeth. The teeth were randomly divided i...

متن کامل

USAF Dental Evaluation & Consultation Service Grinding it Out: Do New Adhesives Bond to Uncut Enamel? (1/03) Microtensile bond strength of self-etching adhesives to ground and unground

This study tested the bond strength of three types of bonding agents to ground and unground enamel, and examined the specimens after testing to see where they had failed. Seventytwo bovine incisors were used in the research. Half of the teeth were assigned to the Ground Enamel Group and were prepared by grinding the facial to produce a flat surface for bonding. The other 32 teeth (the Unground ...

متن کامل

Effect of Er: YAG laser, diamond bur and sandblasting on the microtensile bond strength of the composite to noncarious cervical lesions

Background and Aims: Restoration of non-carious cervical lesions (NCCLs) is challenging due to the difficulty of adhesion of dental tissues. The aim of this study was to investigate the effects of three methods of surface treatments using diamond bur, Er: YAG laser and sandblasting on the microtensile bond strength of resin composite to the noncarious dentin in cervical lesions. Materials and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of adhesive dentistry

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2004