In vitro multichannel single-unit recordings of action potentials from mouse sciatic nerve.

نویسندگان

  • L Chen
  • S J Ilham
  • T Guo
  • S Emadi
  • B Feng
چکیده

Electrode arrays interfacing with peripheral nerves are essential for neuromodulation devices targeting peripheral organs to relieve symptoms. To modulate (i.e., single-unit recording and stimulating) individual peripheral nerve axons remains a technical challenge. Here, we report an in vitro setup to allow simultaneous single-unit recordings from multiple mouse sciatic nerve axons. The sciatic nerve (~30 mm) was harvested and transferred to a tissue chamber, the ~5mm distal end pulled into an adjacent recording chamber filled with paraffin oil. A custom-built multi-wire electrode array was used to interface with split fine nerve filaments. Single-unit action potentials were evoked by electrical stimulation and recorded from 186 axons, of which 49.5% were classed A-type with conduction velocities (CV) greater than 1 m/s and 50.5% were C-type (CV < 1 m/s). The single-unit recordings had no apparent bias towards A- or C-type axons, were robust and repeatable for over 60 minutes, and thus an ideal opportunity to assess different neuromodulation strategies targeting peripheral nerves. For instance, ultrasonic modulation of action potential transmission was assessed using the setup, indicating increased nerve conduction velocity following ultrasound stimulus. This setup can also be used to objectively assess the design of next-generation electrode arrays interfacing with peripheral nerves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Odontobuthus Doriae Scorpion Venom on Mouse Sciatic Nerve

Temporary paralysis is a rare manifestation of envenoming following the yellow Iranian scorpion, Odontobuthus doriae (O. doriae). Thus, to elucidate the underlying mechanism, we investigated the neurotoxic effect of venom in the sciatic nerve, the possible mechanism in a mice model. The neurotoxicity and temperature effects in the venom-induced neurotoxicity were examined using the mouse sciati...

متن کامل

Effects of Odontobuthus Doriae Scorpion Venom on Mouse Sciatic Nerve

Temporary paralysis is a rare manifestation of envenoming following the yellow Iranian scorpion, Odontobuthus doriae (O. doriae). Thus, to elucidate the underlying mechanism, we investigated the neurotoxic effect of venom in the sciatic nerve, the possible mechanism in a mice model. The neurotoxicity and temperature effects in the venom-induced neurotoxicity were examined using the mouse sciati...

متن کامل

Multichannel thin-film electrode for intramuscular electromyographic recordings.

It is currently not possible to record electromyographic (EMG) signals from many locations concurrently inside the muscle in a single wire electrode system. We developed a thin-film wire electrode system for multichannel intramuscular EMG recordings. The system was fabricated using a micromachining process, with a silicon wafer as production platform for polyimide-based electrodes. In the curre...

متن کامل

Electrophysiological Motor Unit Number Estimation (MUNE) Measuring Compound Muscle Action Potential (CMAP) in Mouse Hindlimb Muscles

Compound muscle action potential (CMAP) and motor unit number estimation (MUNE) are electrophysiological techniques that can be used to monitor the functional status of a motor unit pool in vivo. These measures can provide insight into the normal development and degeneration of the neuromuscular system. These measures have clear translational potential because they are routinely applied in diag...

متن کامل

Single-unit recordings of arterial chemoreceptors from mouse petrosal ganglia in vitro.

A preparation was developed that allows for the recording of single-unit chemoreceptor activity from mouse carotid body in vitro. An anesthetized mouse was decapitated, and each carotid body was harvested, along with the sinus nerve, glossopharyngeal nerve, and petrosal ganglia. After exposure to collagenase/trypsin, the cleaned complex was transferred to a recording chamber where it was superf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical physics & engineering express

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017