An Improved 28 Channel Coil Array for Optic Nerve Imaging

نویسندگان

  • R. Merrill
  • J. Hadley
  • E. Minalga
  • D. Parker
  • S. Vijayakumar
  • S-E. K. Choi
  • L. Bell
چکیده

Methods: The Optic Nerve (ON) coil was constructed using two fiberglass formers that fit together to surround the entire head. The anterior former supports 26 overlapping coil elements in a mask arrangement as shown in Fig. 1. The posterior former supports the neck and head and houses two additional overlapped coil elements, totaling to 28 elements. In this design, the two formers can slide over each other to accommodate any arbitrary head size, while maintaining close coupling near the eyes and around the head in general. This design eliminates the air void regions that occur between the coil elements and the forehead when smaller heads are imaged in one-piece, non-adjustable coil formers. The elements were placed using a soccer ball layout [2]. In addition, the coil elements were designed and placed to optimize parallel imaging along the optic nerve from the orbit to the chiasm. Elements were circular in shape and constructed from 14-gauge wire to minimize any flux shielding effect that might occur when using dense arrays of etched copper loops [3]. Phantom studies were performed using a homemade fiberglass, CuSO4 solution head phantom in a Siemens 3T TIM Trio MRI scanner (Siemens Medical Solutions). Phantom images were used to assess and compare the relative SNR (rSNR) and inverse g-factor maps of the two coils.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phased-array surface coil MR of the orbits and optic nerves.

PURPOSE To devise a practical technique for high-resolution evaluation of the anterior optic apparatus using a phased-array surface coil system, and to evaluate this system in patients with suspected optic pathway abnormalities. METHODS A four-element phased-array coil pair was placed on each side of the head, and signal-to-noise measurements were obtained using a head phantom. Comparison bet...

متن کامل

A 32-channel Receive Array Coil for Pediatric Brain Imaging at 3T

Introduction: Pediatric MRI currently requires general anesthesia to preclude motion artifacts. With highly accelerated image encoding in conjunction motion navigators it may be possible to significantly reduce or even eliminate anesthesia. For research studies of brain development where anesthesia is not possible, improved motion robustness can significantly improve the success rate. Highly pa...

متن کامل

Implementation of a Four-channel Phased-array Coil for Patloc Imaging

Introduction: Non-linear local gradients have been introduced for high-magnetic fields to alleviate problems arising from fast gradient switching and resulting peripheral nerve stimulation [1]. This work is focused on the implementation of a selfconstructed four-channel phased-array coil for multi-parallel PatLoc imaging to study the non-linear geometry of these fields under realistic condition...

متن کامل

Magnetic resonance imaging (MRI) and spectroscopy (MRS) using simultaneous 2-channel acquisitions: Application for mouse brain examination by reconfiguration of a "standard" Bruker spectrometer

In the field of small animal imaging, the interest for phased array coil imaging is growing but high field MR experimental systems with multiple receiver channels are still rare and the upgrade of existing systems is relatively expensive. In this work, a standard 4.7 T Bruker Biospec Avance II spectrometer was modified to allow simultaneous two-channel acquisitions. Modifications were validated...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009