Effects of Orthodontic Mini-implant Diameter on Microdamage

نویسندگان

  • Enrique Cruz
  • Sean Liu
  • Jun Sun
  • Steven B. Blanchard
  • Armando Soto
  • Kelton T Stewart
  • Matthew R. Allen
چکیده

Microdamage reduces bone mechanical properties and thus could possibly contribute to implant failure. The objective of this study was to investigate whether the diameter of mini-implants (MI) affects microdamage generation and whether this differs between the mandible and maxilla due to their contrasting cortical thicknesses. Methods: Maxillary and mandibular quadrants of 5 dogs were randomly assigned to receive, in situ, no intervention (control), pilot drilling only, or pilot drilling plus one of three diameters of MI: 1.4 (n=18), 1.6 (n=18), and 2.0 mm (n=18). Microdamage was assessed on basic fuchsin stained sections using epifluorescence microscopy. Results: No microdamage was found in the non-drilling controls. Pilot drilling produced only minimal microdamage in the maxilla but more microdamage in the mandible. There was significantly higher microdamage generated in the mandible, compared to the maxilla (p<0.05). In the maxil-la, although insertion of all implants produced higher microdamage than the control and pilot drilling, there were no differences between the 3 MI diameters. In the mandible, insertion of implants generated significantly higher microdamage than the control, but it did not produce higher microdamage than pilot drilling. Similarly, no differences in microdamage were found between 3 MI diameters. Conclusion: Insertion of MIs in the mandible produced higher microdamage than in the maxilla, which may explain that the higher MI failure rate in the mandible. Implant diameter did not affect overall microdamage burden in either jaw. Microdamage was mostly generated by pilot drilling through the cortex in the mandible, while microdamage in the maxilla was mainly produced when manual inserting MIs after pilot drilling .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of mini-implant length and diameter on primary stability under loading with two force levels.

Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in b...

متن کامل

Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

OBJECTIVE To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. METHODS Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-im...

متن کامل

Why are mini-implants lost: The value of the implantation technique!

The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the f...

متن کامل

Stress distribution patterns at mini-implant site during retraction and intrusion—a three-dimensional finite element study

BACKGROUND The purpose of this study was to evaluate the stress patterns produced in mini-implant and alveolar bone, for various implant dimensions, under different directions of simulated orthodontic force, using a three-dimensional finite element method. METHODS Eight finite element (FE) models of mini-implant and bone were generated with insertion angles of 30° and 60°, diameters of 1 and ...

متن کامل

Morphological evaluation of the active tip of six types of orthodontic mini-implants.

OBJECTIVE To morphologically evaluate the active tip of six different types of self-drilling mini-implants for orthodontic anchorage. METHODS Images of the active tips of the mini-implants were obtained with a Zeiss optical microscope Stemi 200-C, with magnification of 1.6X. The images of the surface were viewed with the Axio Vision program (Zeiss, Jena, Germany) to calculate linear and angul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012