Arsenic species interactions with a porous carbon electrode as determined with an electrochemical quartz crystal microbalance.

نویسندگان

  • Emilia Morallón
  • Joaquín Arias-Pardilla
  • J M Calo
  • D Cazorla-Amorós
چکیده

The interactions of arsenic species with platinum and porous carbon electrodes were investigated with an electrochemical quartz crystal microbalance (EQCM) and cyclic voltammetry in alkaline solutions. It is shown that the redox reactions in arsenic-containing solutions, due to arsenic reduction/deposition, oxidation/desorption, and electrocatalyzed oxidation by Pt can be readily distinguished with the EQCM. This approach was used to show that the arsenic redox reactions on the carbon electrode are mechanistically similar to that on the bare Pt electrode. This could not be concluded with just classical cyclic voltammetry alone due to the obfuscation of the faradaic features by the large capacitative effects of the carbon double layer.For the porous carbon electrode, a continual mass loss was always observed during potential cycling, with or without arsenic in the solution. This was attributed to electrogasification of the carbon. The apparent mass loss per cycle was observed to decrease with increasing arsenic concentration due to a net mass increase in adsorbed arsenic per cycle that increased with arsenic concentration, offsetting the carbon mass loss. Additional carbon adsorption sites involved in arsenic species interactions are created during electrogasification, thereby augmenting the net uptake of arsenic per cycle.It is demonstrated that EQCM, and in particular the information given by the behavior of the time derivative of the mass vs. potential, or massogram, is very useful for distinguishing arsenic species interactions with carbon electrodes. It may also prove to be effective for investigating redox/adsorption/desorption behavior of other species in solution with carbon materials as well.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simultaneous electrochemical impedance and quartz crystal microbalance study on antihuman immunoglobulin G adsorption and human immunoglobulin G reaction.

The quartz crystal microbalance (QCM), in combination with electrochemical impedance spectroscopy (EIS), has been utilized to monitor in situ antihuman IgG (hIgG) adsorption on bare poly(o-phenylenediamine) (PPD)- and 1-dodecanethiol (C12SH)-modified Au electrodes and succeeding human IgG reaction, respectively. The resonant frequency (f) and the motional resistance (R(1)) of the piezoelectric ...

متن کامل

Electropolymerization and doping/dedoping properties of polyaniline thin films as studied by electrochemical-surface plasmon spectroscopy and by the quartz crystal microbalance

The electropolymerization and doping/dedoping properties of polyaniline ultrathin films on Au electrode surfaces were investigated by a combination of in situ electrochemical techniques, i.e., electrochemical surface plasmon spectroscopy (ESPR) and the electrochemical quartz crystal microbalance (EQCM). In the ESPR measurements, we employed two wavelengths, i.e., 632.8 and 1152 nm in order to d...

متن کامل

Design and Characterization of a Rotating Electrochemical Quartz-Crystal-Microbalance Electrode

A novel design for a rotating electrochemical quartz-crystal microbalance (rEQCM) which includes easily and reproducibly exchangeable quartz-crystal holders is described. The rEQCM allows for well-controlled mass-transport conditions at the working electrode on a 10 MHz quartz crystal. Together with the flexibility of the proposed design, this makes it useful for a wide range of applications in...

متن کامل

Mechanism of formation and construction of self-assembled myoglobin/hyaluronic acid multilayer films: an electrochemical QCM, impedance, and AFM study.

Self-assembled multilayer films of hyaluronic acid (HA) and the protein myoglobin (Mb) were built up layer by layer on Au covered quartz crystal microbalance (AuQCM) electrode substrates. Film formation and growth were monitored by an electrochemical quartz crystal microbalance (EQCM), and the step-by-step construction was investigated through quantification of the mass variation corresponding ...

متن کامل

Electrochemical quartz crystal microbalance study of polyelectrolyte film growth under anodic conditions

Coating hard materials such as Pt with soft polymers like poly-L-lysine is a well-established technique for increasing electrode biocompatibility. We have combined quartz crystal microgravimetry with dissipation with electrochemistry (EQCM-D) to study the deposition of PLL onto Pt electrodes under anodic potentials. Our results confirm the change in film growth over time previously reported by ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Electrochimica acta

دوره 54 16  شماره 

صفحات  -

تاریخ انتشار 2009