Brachial blood pressure-independent relations between radial late systolic shoulder-derived aortic pressures and target organ changes.
نویسندگان
چکیده
Central aortic blood pressure (BP; BPc) predicts outcomes beyond brachial BP. In this regard, the application of a generalized transfer function (GTF) to radial pulse waves for the derivation of BPc is an easy and reproducible measurement technique. However, the use of the GTF may not be appropriate in all circumstances. Although the peak of the second shoulder of the radial waveform (P2) is closely associated with BPc, and, hence, BPc may be assessed without the need for a GTF, whether P2-derived BPc is associated with adverse cardiovascular changes independent of brachial BP is uncertain. Thus, P2- and GTF-derived aortic BPs were assessed using applanation tonometry and SphygmoCor software. Left ventricular mass was indexed for height(1.7) (n=678) and carotid intima-media thickness (IMT; n=462) was determined using echocardiography and vascular ultrasound. With adjustments for nurse-derived brachial pulse pressure (PP), P2-derived central PP was independently associated with left ventricular mass indexed for height(1.7) (partial r=0.18; P<0.0001) and IMT (partial r=0.40; P<0.0001). These relations were similar to nurse-derived brachial PP-independent relations between GTF-derived central PP and target organ changes (left ventricular mass indexed for height(1.7): partial r=0.17, P<0.0001; IMT: partial r=0.37, P<0.0001). In contrast, with adjustments for central PP, nurse-derived brachial PP-target organ relations were eliminated (partial r=-0.21 to 0.05). Twenty-four-hour, day, and night PP-target organ relations did not survive adjustments for nurse-derived brachial BP. In conclusion, central PP derived from P2, which does not require a GTF, is associated with cardiovascular target organ changes independent of brachial BP. Thus, when assessing adverse cardiovascular effects of aortic BP independent of brachial BP, P2-derived measures may complement GTF-derived measures of aortic BP.
منابع مشابه
Central Blood Pressure Brachial Blood Pressure–Independent Relations Between Radial Late Systolic Shoulder-Derived Aortic Pressures and Target Organ Changes
Central aortic blood pressure (BP; BPc) predicts outcomes beyond brachial BP. In this regard, the application of a generalized transfer function (GTF) to radial pulse waves for the derivation of BPc is an easy and reproducible measurement technique. However, the use of the GTF may not be appropriate in all circumstances. Although the peak of the second shoulder of the radial waveform (P2) is cl...
متن کاملNoninvasive pulse waveform analysis in clinical trials: similarity of two methods for calculating aortic systolic pressure.
BACKGROUND Concerns persist about the validity of generalized transfer function-derived, aortic blood-pressure measurements during the administration of vasoactive agents in clinical trials. Hence, we compared this transfer-function method with another, which estimates aortic systolic pressure directly from the late systolic shoulder of the radial pressure wave, after administration of placebo,...
متن کاملCentral Blood Pressure/Aortic Stiffness Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure
The prognostic value of central systolic blood pressure has been established recently. At present, its noninvasive assessment is limited by the need of dedicated equipment and trained operators. Moreover, ambulatory and home blood pressure monitoring of central pressures are not feasible. An algorithm enabling conventional automated oscillometric blood pressure monitors to assess central systol...
متن کاملCentral aortic pressure and clinical outcomes.
Conventional brachial blood pressure (BP) measurement by sphygmomanometry is simple and has remained the gold standard for the measurement of BP for over a century. Moreover, it is well established that brachial BP levels are predictive of cardiovascular morbidity and mortality. When we measure brachial BP, we do so with the assumption that the pressure measured over the brachial artery accurat...
متن کاملImpact of heart rate on central aortic pressures and hemodynamics: analysis from the CAFE (Conduit Artery Function Evaluation) study: CAFE-Heart Rate.
OBJECTIVES The CAFE (Conduit Artery Function Evaluation) study showed less effective central aortic pressure lowering with atenolol-based therapy versus amlodipine-based therapy in people with hypertension. The present study examined the importance of heart rate (HR) as a determinant of this effect. BACKGROUND Recent analyses have suggested that beta-blockers are less effective at reducing ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hypertension
دوره 59 4 شماره
صفحات -
تاریخ انتشار 2012