Silicone-diffractive versus acrylic-refractive supplementary iols: visual performance and manual handling.

نویسندگان

  • Jens Schrecker
  • Sandra Blass
  • Achim Langenbucher
چکیده

PURPOSE To compare visual outcome and manual handling of additional multifocal sulcus-fixated intraocular lenses (IOLs) of different materials and lens concepts. METHODS Visual outcomes after implantation of a monofocal IOL in the capsular bag followed by implantation of a sulcus-fixated multifocal IOL (MIOL) in patients with cataract were assessed. Patients were randomly assigned to receive either the refractive Sulcoflex 653F (Rayner Surgical GmbH, Bamberg, Germany) (35 eyes) or the diffractive MS 714 PB Diff (Dr. Schmidt Intraocularlinsen GmbH, St. Augustin, Germany) (33 eyes) additional MIOL. Three months postoperatively, visual acuity at far, intermediate, and near distance and contrast sensitivity under different conditions were evaluated. Patients with binocular implantation were asked to rate their subjective quality of vision. RESULTS No complications occurred during or after surgery. No significant differences in uncorrected and corrected distance visual acuity at all distances were found between groups. All eyes achieved uncorrected visual acuity of 0.3 logMAR (20/40 Snellen) or better at all distances. Contrast sensitivity was significantly better in the diffractive MS 714 PB Diff group than in the refractive Sulcoflex 653F group under all conditions. The refractive Sulcoflex 653F group experienced more photic phenomena (81%) than the diffractive MS 714 PB Diff group (25%), but the disturbances were scored as mild to moderate in most cases (93%/100%). The unfolding procedure of the acrylic Sulcoflex 653F IOL was smoother and more controllable than that of the silicone MS 714 PB Diff IOL. CONCLUSIONS Both additional MIOLs performed well in terms of far, intermediate, and near vision and enabled patients to handle almost all areas of activity without glasses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-Term Stability of Diffractive Multifocal Intraocular Lenses: Contralateral Comparison between Silicone and Acrylic Materials

Objective: To compare visual function stability between silicone and hydrophobic acrylic materials of diffractive multifocal intraocular lenses (MF-IOLs). Methods: This retrospective study reviewed clinical records of 10 patients who received a silicone MF-IOL in the first eye and hydrophobic acrylic lens in the fellow eye. Intra-individual differences in logMAR corrected distance visual acuity...

متن کامل

Interaction with intraocular lens materials: does heavy silicone oil act like silicone oil?

PURPOSE To determine the interaction of heavy silicone oil with various intraocular lens (IOL) materials and whether heavy silicone oil covers the silicone IOL optic as silicone oil does. SETTING Department of Ophthalmology, Dokuz Eylul University, Izmir, Turkey. METHODS The study group comprised 5 poly(methyl methacrylate) (PMMA) IOLs, 4 foldable silicone IOLs, 5 foldable hydrophilic acryl...

متن کامل

Bilateral implantation of asymmetrical diffractive multifocal intraocular lenses.

OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...

متن کامل

Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses.

PURPOSE To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University o...

متن کامل

Comparison of outcomes with multifocal intraocular lenses: a meta-analysis

PURPOSE To compare the clinical outcome of different multifocal intraocular lenses (IOLs) based on information reported in the international literature. METHODS All comparative clinical trials that involved implanting at least one multifocal IOL in patients with cataract or presbyopia were extracted from the literature. Clinical outcomes included uncorrected near visual acuity, uncorrected di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2014