Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract.
نویسندگان
چکیده
PURPOSE To test correlations between Scheimpflug optical densitometry and ocular higher-order aberrations (HOAs) in patients with mild nuclear cataract. SETTING Cornea and Refractive Surgery Department, Hospital de Braga, Braga, Portugal. DESIGN Retrospective single-center study. METHODS In eyes with mild nuclear cataract, lens densitometry was evaluated by Scheimpflug imaging (Pentacam HR), which provided an objective quantification (mean density and maximum density) and grading (nuclear staging score) of the crystalline lens. A visual function analyzer that combines ray-tracing aberrometry and Placido disk-based topography (iTrace) was used to evaluate the total ocular and internal HOAs. RESULTS The study comprised 40 eyes of 30 patients. The mean density of the lens nucleus was 8.99% ± 0.76% (SD) (range 7.5% to 10.8%), and the mean maximum density was 27.96% ± 6.97% (range 16.9% to 56.1%). Regarding the score of nuclear staging of the Scheimpflug device, 28 eyes had level 0 and 12 eyes had level 1. Significant positive correlations were found between the mean density and maximum density parameters and the internal HOAs (ρ = 0.661, P < .001 and ρ = 0.570, P < .001, respectively). CONCLUSIONS There were significant correlations between the quantification parameters derived from Scheimpflug lens densitometry and ocular HOAs. The integration of these technologies can help in clinical decision making and in understanding the subjective symptoms of patients with mild nuclear cataracts. FINANCIAL DISCLOSURE Dr. Ambrósio is a consultant to Oculus Optikgeräte GmbH, Alcon Surgical, Inc., and Carl Zeiss Meditec AG. None of the other authors has a financial or proprietary interest in any material or method mentioned.
منابع مشابه
Wavefront analysis in eyes with nuclear or cortical cataract.
PURPOSE To compare the higher-order aberrations of the oculus (whole eye) and cornea in eyes with mild cortical or nuclear cataract and to estimate the effect of ocular higher-order aberrations on the loss of contrast sensitivity using wavefront analysis. DESIGN Observational case series. METHODS Six eyes of four patients with mild nuclear cataract, 18 eyes of 14 patients with mild cortical...
متن کاملComparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software.
PURPOSE To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS) III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. METHODS One hundred and one eyes from 101 patients with age-related nuclear cataract were submitted to clinical examination for lens grading score using LOCS III. According to...
متن کاملStudy of nuclear cataract progression using the National Eye Institute Scheimpflug system.
AIMS A study was conducted to determine the capability of the recently developed National Eye Institute (NEI) Scheimpflug cataract imaging system in detecting changes in the nuclear region of the lens over a 1 year period. METHODS Twenty five eyes with pure nuclear cataracts with mean nuclear densities < or = 0.30 optical density units (ODU) as well as 30 normal control eyes were each examine...
متن کاملRepeatability and validity of lens densitometry measured with Scheimpflug imaging.
PURPOSE To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. SETTING Eye Clinic, Queensland University of Technology, Brisbane, Australia. METHODS This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through...
متن کاملQuantitating nuclear opacification in color Scheimpflug photographs.
PURPOSE To test the validity of the color component subtraction method, a new objective technique of measuring nuclear cataract, and to correlate the tangent values of the different degrees of nuclear opacities to their corresponding subjective nuclear cataract grading using the Lens Opacities Classification System II and to another objective method of measuring nuclear cataract. METHODS Dens...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 42 3 شماره
صفحات -
تاریخ انتشار 2016