Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study

نویسندگان

  • Alexaner Synek
  • Lars Borgmann
  • Hannes Traxler
  • Wolfgang Huf
  • Ekkehard Euler
  • Yan Chevalier
  • Sebastian F Baumbach
چکیده

BACKGROUND Symptomatic extensor tendon irritation is a frequent complication in volar plate osteosynthesis of distal radius fractures. It is typically caused by dorsal screw protrusion and overdrilling of the dorsal cortex. The use of self-drilling locking screws (SDLS) could overcome both causes. The practical applicability of SDLS depends on two prerequisites: (1) the feasibility of preoperative distal screw length determination, and (2) sufficient primary biomechanical stability of SDLS compared to standard locking screws (SLS). METHODS We first assessed the feasibility of preoperative screw length determination (1): Distal radius width, depth and distal screw lengths were measured in 38 human radii. Correlations between distal radius width and depth were assessed, a cluster analysis (Ward's method and squared Euclidean distance) for distal radius width conducted, and intra-cluster screw lengths analyzed (ANOVA). The biomechanical performance of SDLS (2) was assessed by comparison to SLS in a distal radius fracture model (AO-23 A3). 75 % distal screw length was chosen for both groups to simulate a worst-case scenario. Uniaxial compression tests were conducted to measure stiffness, elastic limit, maximum force and residual tilt. Statistics comprised of independent sample t-tests and a Bonferroni correction (p < 0.0125). RESULTS (1) Distal radius width and depth showed a high correlation (R (2)  = 0.79; p < 0.001). Three distal radius width clusters could be identified: small <34 mm; medium 34-36.9 mm; large >36.9 mm. ANOVA and Tukey post-hoc analysis revealed significantly different volar-dorsal depths (p < 0.05) for nearly all screws. (2) To assess biomechanical stability nine specimens were tested each; no significant differences were found between the SDLS and SLS groups. CONCLUSIONS This feasibility study demonstrates that (1) distal radius width can be used as a predictor for distal screw length and (2) that SDLS provides mechanical stability equivalent to SLS. These results highlight the feasibility of applying SDLS screws in volar plate osteosynthesis at least in extraarticular fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of distal screw length on the primary stability of volar plate osteosynthesis—a biomechanical study

BACKGROUND Extensor tendon irritation is one of the most common complications following volar locking plate osteosynthesis (VLPO) for distal radius fractures. It is most likely caused by distal screws protruding the dorsal cortex. Shorter distal screws could avoid this, yet the influence of distal screw length on the primary stability in VLPO is unknown. The aim of this study was to compare 75 ...

متن کامل

Distal Radius Fractures: What Cannot Be Fixed With a Volar Plate?—The Role of Fragment-Specific Fixation in Modern Fracture Treatment

The advent of volar fixed-angle plate osteosynthesis has greatly improved the technical ability of the surgeon to treat distal radius fractures and expanded the indications for operative treatment. Nevertheless, the volar plate is not a panacea for all distal radius fractures. Increasingly, it has been recognized that the loss of fixation, secondary displacement, and lack of stability can occur...

متن کامل

Is minimally invasive application by intramedullary osteosynthesis in comparison with volar plating real benefit in the treatment of distal radius fractures?

PURPOSE OF THE STUDY Can minimally invasive intramedullary osteosynthesis of distal radius fractures provide better therapeutic results than multidirectional locking plates. Retrospective study of 68 patients operated for distal radius fractures, 18 were treated with intramedullary X-screw (XSCR) fixation and 50 with the multidirectional angle-stable plate system (APTUS). The evaluation at 1-ye...

متن کامل

Various volar shapes of the distal radius and its implications on volar plate osteosynthesis

Volar plate fi xation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variati...

متن کامل

Anatomy of the distal volar radius and its implications on volar plate osteosynthesis

Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016