Experimental study of fast and ultrafast T2-weighted imaging sequences using AMI-25 superparamagnetic iron oxide (SPIO).
نویسندگان
چکیده
The objective of this study was to evaluate fast and ultrafast T2-weighted images (T2WI), including echo planar imaging (EPI), using an AMI-25 agar phantom. Image quality for conventional spin echo (CSE) and turbo spin echo (TSE) was almost equivalent. In high-resolution TSE, image quality was highest due to the use of a 512 x 256 matrix. Half-Fourier single-shot turbo SE (HASTE) was associated with blurring of images, and turbo-gradient SE (TGSE) showed a deterioration of image quality. EPI also suffered from poor image quality because this method is very sensitive to magnetic field inhomogeneity. CSE showed good signal-to-noise ratio (S/N) and contrast ratio (CR), but also required the longest imaging times. Among the TSE sequences, TSE with a short echo train length (ETL) was superior in terms of S/N. The CR of EPI and fast low angle shot (FLASH) images were improved in proportion to the effective echo time (TE). At present, TSE is inferior to CSE in terms of S/N and CR. However, taking into consideration scanning time, TSE with a short ETL is thought to be suitable for routine examinations. Effective TE is an important factor in gradient echo (GRE) examinations.
منابع مشابه
Investigation of SPIO T1-signature: Positive Contrast using Ultrashort TE Imaging
Purpose: Superparamagnetic iron oxide (SPIO) nanoparticles are efficient contrast agents for molecular and cellular MR imaging [1]. They are usually considered to be negative contrast agents, since their magnetic moment causes signal dephasing which results in signal voids on T2* weighted images. However SPIO agents also have intrinsic T1 shortening properties [2] that can induce signal enhance...
متن کاملSensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study
BACKGROUND Susceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences. OBJECTIVES This study aims to assess the sensitivity of SWI in detecting SPIO nanoparticle-labeled, human bone marrow-derived...
متن کاملSuperparamagnetic iron oxide-enhanced MR imaging of head and neck lymph nodes.
PURPOSE To compare findings on superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) images of the head and neck with those from resected lymph node specimens and to determine the effect of such imaging on surgical planning in patients with histopathologically proved squamous cell carcinoma of the head and neck. MATERIALS AND METHODS Thirty patients underwent MR imaging with no...
متن کاملDiffusion-Weighted MR Imaging before and after Contrast Enhancement with Superparamagnetic Iron Oxide for Assessment of Hepatic Metastasis
PURPOSE The purpose of our study was to validate diffusion-weighted MRI (DWI) before and after superparamagnetic iron oxide (SPIO) injection for assessment of hepatic metastases. MATERIALS AND METHODS Eighty-six hepatic metastases (size range, 0.3-4.7 cm; mean, 1.5 cm) verified pathologically or by follow-up imaging studies in 22 consecutive patients (17 men and 5 women; 44-83 years; mean age...
متن کاملIron particles enhance visualization of experimental gliomas with high-resolution sonography.
BACKGROUND AND PURPOSE Intraoperative MR imaging and sonography are used for navigation during neurosurgical procedures. The purpose of this experimental study was to evaluate the potential of high-resolution sonography using superparamagnetic iron oxide (SPIO) particles as a contrast medium to delineate brain tumors and to relate these findings with those of MR imaging. METHODS C6 gliomas we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta medica Okayama
دوره 55 1 شماره
صفحات -
تاریخ انتشار 2001