A preliminary assessment of the effects of ATI-2042 in subjects with paroxysmal atrial fibrillation using implanted pacemaker methodology

نویسندگان

  • Anita Arya
  • John Silberbauer
  • Sam L. Teichman
  • Peter Milner
  • Neil Sulke
  • A. John Camm
چکیده

AIMS ATI-2042 (budiodarone) is a chemical analogue of amiodarone with a half life of 7 h. It is electrophysiologically similar to amiodarone, but may not have metabolic and interaction side effects. The sophisticated electrocardiograph logs of advanced DDDRP pacemakers were used to monitor the efficacy of ATI-2042. The aim of this study was to determine the preliminary efficacy and safety of ATI-2042 in patients with paroxsymal atrial fibrillation (PAF) and pacemakers. METHODS AND RESULTS Six women with AF burden (AFB) between 1 and 50% underwent six sequential 2-week study periods. Patients received 200 mg bid of ATI-2042 during Period 2 (p2), 400 mg bid during p3, 600 mg bid during p4, 800 mg bid during p5, and no drug during baseline and washout (p1 and p6). Pacemaker data for the primary outcome measure AFB were downloaded during each period. Mean AFB decreased between baseline and all doses: AFB at baseline (SD) was 20.3 +/- 14.6% and mean AFB at 200 mg bid was 5.2 +/- 4.2%, at 400 mg bid 5.2 +/- 5.2%, at 600 mg bid 2.8 +/- 3.4%, and at 800 mg bid 1.5 +/- 0.5%. The mean reductions in AFB at all doses of ATI-2042 were statistically significant (P < 0.005). Atrial fibrillation burden increased in washout. Atrial fibrillation episodes tended to increase with ATI-2042, but this was offset by substantial decreases in episode duration. ATI-2042 was generally well tolerated. CONCLUSION ATI-2042 effectively reduced AFB over all doses studied by reducing mean episode duration. A large-scale study will be required to confirm this effect.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker therapy in sino-atrial block complicated by paroxysmal tachycardia.

Pacemakers were implanted in 10 of 14 patients with dizziness and syncopal episodes of long duration, due to sino-atrial block. Paroxysmal supraventricular tachycardia, notably atrial fibrillation, had occurred in 6 patients. Medical treatment was unsatisfactory in 3 of these and pacemaker therapy was given. This abolished both syncope and paroxysmal tachycardia. Sinoatrial block and supraventr...

متن کامل

Patients With Sick Sinus Syndrome

Background. The goal of the report was to study the long-term incidence and the independent predictors for chronic atrial fibrillation and stroke in 507 paced patients with sick sinus syndrome, adjusting for differences in baseline clinical variables with multivariate analysis. Methods and Results. From 1980 to 1989, we implanted 376 dual-chamber, 19 atrial, and 112 ventricular pacemakers to tr...

متن کامل

Patients With Sick Sinus Syndrome Relevance of Clinical Characteristics and Pacing Modalities

Background. The goal of the report was to study the long-term incidence and the independent predictors for chronic atrial fibrillation and stroke in 507 paced patients with sick sinus syndrome, adjusting for differences in baseline clinical variables with multivariate analysis. Methods and Results. From 1980 to 1989, we implanted 376 dual-chamber, 19 atrial, and 112 ventricular pacemakers to tr...

متن کامل

Assessment of P-wave indices as atrial fibrillation predictors in psoriasis patients

Background: Psoriasis is a prevalent chronic T cell mediated inflammatory skin disorder. Recent studies have reported an increase in the incidence of arrhythmia in psoriasis patients who run an excessive risk of metabolic syndrome and cardiovascular diseases. P-wave dispersion (PWD) and duration are important electrocardiographic (ECG) markers employed to anticipate the risk of atrial arrhythmi...

متن کامل

Right versus left atrial pacing in patients with sick sinus syndrome and paroxysmal atrial fibrillation (Riverleft study): study protocol for randomized controlled trial

BACKGROUND The incidence of sick sinus syndrome will increase due to population ageing. Consequently, this will result in an increase in the number of pacemaker implantations. The atrial lead is usually implanted in the right atrial appendage, but this position may be ineffective for prevention of atrial fibrillation. It has been suggested that pacing distally in the coronary sinus might be mor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2009