Three-Dimensional Finite Elemental Analysis of Bone Stress near an Implant Placed at the Border between Mandible and Fibular Graft in Mandibular Reconstruction

نویسندگان

  • Yukawa Ken
  • Tachikawa Noriko
  • Kasugai Shohei
چکیده

Purpose: The aim of the present study was to use finite elemental analysis (FEA) to evaluate bone stress near an implant placed at the border between the mandible and fibular graft in mandibular reconstruction. Materials and Methods: A fibular model (FM) and transplantation model (TM) were constructed for FEA. In TM, mandible was on the mesial side and the fibular graft was on the distal side. The implant was positioned at the center of both bone models. In TM, it was placed on the border between the mandible and fibular graft. A 10-mm implant was used in the monocortical model and a 15-mm implant was used in the bicortical model. The loading force was set at 100 N, the angle was set at 90 ̊, and the loading position was set as center, mesial, or distal on the upper surface of the prosthesis. Von Mises equivalent stress values of the bone near the implant collar and apex at the middle line between buccal and lingual side were measured. Results: In all models, stress values were significantly lower with center loading than with distal loading and mesial loading. In center loading, the stress values were significantly lower in the bicortical model than in the monocortical model. There were no significant differences in stress values between FM and TM in all conditions. Conclusions: Bone stress was least with the center loading position, which was further decreased by bicortical fixation. There was no increase in mechanical stress associated with placing an implant at the border between the mandible and the fibular graft.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Analysis of Fibular Single Graft and Fibular Double-barrel Graft for Mandibular Reconstruction

BACKGROUND High-quality mandibular reconstruction using vascularized free fibular graft is necessary to provide an osseointegrated dental implant and fixed denture. An appropriate crown-implant ratio is needed, and a good match between bones is extremely important. There are no articles describing the analysis and evaluation of both the fibula and mandible in the same patients. METHODS Comput...

متن کامل

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

Three-dimensional finite element analysis of implant-supported crown in fibula bone model

PURPOSE The purpose of this study was to compare stress distributions of implant-supported crown placed in fibula bone model with those in intact mandible model using three-dimensional finite element analysis. MATERIALS AND METHODS Two three-dimensional finite element models were created to analyze biomechanical behaviors of implant-supported crowns placed in intact mandible and fibula model....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015